Technical Data Sheet
FI 72.0239.0320E
Page 100 / 108
80 (79)
50 (4F)
Number of cells
X
81 (80)
51 (50)
Value timer T1 (from 3 to 255 1/100th of second)
X
X
82 (81)
52 (51)
Value timer T2 (from 1 to 255 seconds)
X
X
83 (82)
53 (52)
Value timer T2’ (from 1 to 255 seconds)
X
X
84 (83)
54 (53)
Value timer T3 (from 0 to 255 seconds)
X
X
85 (84)
55 (54)
Value timer T4 (from 0 to 255 seconds)
X
X
86 (85)
56 (55)
Value timer T5 (from 0 to 255 seconds)
X
X
87 (86)
57 (56)
Value timer T6 (from 0 to 255 seconds)
X
X
88 (87)
58 (57)
Value timer T7 (from 0 to 255 seconds)
X
X
89 (88)
59 (58)
Value timer T8 (from 0 to 255 seconds)
X
X
90 (89)
5A (59)
Value timer T9 (from 0 to 255 seconds)
X
X
91 (90)
5B (5A)
Value timer T10 (from 1 to 999 seconds)
X
X
Isolated headers. 1 bit by header. Bit=1 if the header is isolated (continuation to ask for isolation or fault)
92 (91)
5C (5B)
Isolated header n°1 to 16 (LSB : header n°1, MSB : header n°16)
X
93 (92)
5D
(5C)
Isolated header n°17 to 32 (LSB : header n°17, MSB : header n°32)
X
94 (93)
5E (5D)
Number current cell
X
95 (94)
5F (5E)
Number next cell
X
96 (95)
60 (5F)
Number current way
X
97 (96)
61 (60)
Number next way
X
98 (97)
62 (61)
Number current time:
=0: waiting/off
=1: T1 in progress
=2: T2 in progress
=3: T3 in progress
=5: T5 in progress
=6: T6 in progress
=7: T7 in progress
=11: stop
=12: a/c missing
=14: T2’ in progress
=15: T9 in progress
=20: stop on image
=22: awaiting reinflation
X
Outputs status on outputs modules (the first 256 – excluding pulses SV). 1 bit by output. Bit=1 if the output is activated:
99 (98)
63 (62)
outputs 1 to 16 (LSB : output 1, MSB : output 16)
X
100 (99)
64 (63)
outputs 17 to 32 (LSB : output 17, MSB : output 32)
X
101 (100)
65 (64)
outputs 33 to 48 (LSB : output 33, MSB : output 48)
X
102 (101)
66 (65)
outputs 49 to 64 (LSB : output 49, MSB : output 64)
X
103 (102)
67 (66)
outputs 65 to 80 (LSB : output 65, MSB : output 80)
X
104 (103)
68 (67)
outputs 81 to 96 (LSB : output 81, MSB : output 96)
X
105 (104)
69 (68)
outputs 97 to 112 (LSB : output 97, MSB : output 112)
X
106 (105)
6A (69)
outputs 113 to 128 (LSB : output 113, MSB : output 128)
X
107 (106)
6B (6A)
outputs 129 to 144 (LSB : output 129, MSB : output 144)
X
108 (107)
6C (6B)
outputs 145 to 160 (LSB : output 145, MSB : output 160)
X
109 (108)
6D (6C)
outputs 161 to 176 (LSB : output 161, MSB : output 176)
X
110 (109)
6E (6D)
outputs 177 to 192 (LSB : output 177, MSB : output 192)
X
111 (110)
6F (6E)
outputs 193 to 208 (LSB : output 193, MSB : output 208)
X
112 (111)
70 (6F)
outputs 209 to 224 (LSB : output 209, MSB : output 224)
X
113 (112)
71 (70)
outputs 225 to 240 (LSB : output 225, MSB : output 240)
X
114 (113)
72 (71)
outputs 241 to 256 (LSB : output 241, MSB : output 256)
X
Counter number of total pulses (from 0 to 99.999.999):
115 (114)
73 (72)
number of millions (0 to 99)
X
116 (115)
74 (73)
number of thousands (0 to 999)
X
117 (116)
75 (74)
number of units (0 to 999)
X
( ex: if MW115=03 , MW116=185 and MW117=763 then counter value = 03185763 pulses)
Counter number of user pulses (from 0 to 99.999.999):
118 (117)
76 (75)
number of millions (0 to 99)
X
119 (118)
77 (76)
number of thousands (0 to 999)
X
120 (119)
78 (77)
number of units (0 to 999)
X
( ex: if MW118=00 , MW119=021 and MW120=250 then counter value = 00021250 pulses )
Counter number of total cycles (from 0 to 999.999):
121 (120)
79 (78)
number of thousands (0 to 999)
X
122 (121)
7A (79)
number of units (0 to 999)
X
( ex: if MW121=045 and MW122=240 then counter value = 045240 cycles )
Counter number of user cycles (from 0 to 999.999):
123 (122)
7B (7A)
number of thousands (0 to 999)
X
124 (123)
7C (7B)
number of units (0 to 999)
X
( ex: if MW123=002 and MW124=006 then counter value = 002006 cycles )
Summary of Contents for SFX+NETWORK
Page 21: ...Technical Data Sheet FI 72 0239 0320E Page 21 108 SIGNALLING...
Page 22: ...Technical Data Sheet FI 72 0239 0320E Page 22 108 CONNECTIONS CONNECTION EXAMPLE...
Page 24: ...Technical Data Sheet FI 72 0239 0320E Page 24 108 CONNECTIONS CONNECTION EXAMPLE...
Page 26: ...Technical Data Sheet FI 72 0239 0320E Page 26 108 CONNECTIONS CONNECTION EXAMPLE...
Page 28: ...Technical Data Sheet FI 72 0239 0320E Page 28 108 CONNECTIONS CONNECTION EXAMPLE...
Page 31: ...Technical Data Sheet FI 72 0239 0320E Page 31 108 CONNECTIONS CONNECTION EXAMPLE...
Page 34: ...Technical Data Sheet FI 72 0239 0320E Page 34 108 CONNECTIONS...
Page 37: ...Technical Data Sheet FI 72 0239 0320E Page 37 108 SFX MODULE POWER CONSUMPTION...
Page 38: ...Technical Data Sheet FI 72 0239 0320E Page 38 108...
Page 85: ...Technical Data Sheet FI 72 0239 0320E Page 85 108...