OPEN/CLOSE CONTROL
This parameter is used in the case of a configuration with a control of opened/closed cells.
Choice whether or not the positioning control cells should be performed.
If choice « YES » : the positioning inputs « opened cell » and « closed cell » are checked.
If choice « NO » : the positioning inputs « opened cell » and « closed cell » are ignored.
-
Place the arrow on OPEN/CLOSE CONTROL
and press the
button and the following display
appears:
Note: Protected by code! appears if protection is activated.
To change the choice, use
buttons and press the button to store the choice and return to select
menu.
DUST INPUT TYPE
This parameter is used in the case of a configuration with a dust emission control. It specifies the type of
the input used for the control.
-
If choice « INACTIVE » : the dust emission control is disabled.
-
If choice « DIRECT (0=OK) » : the type of the input is « direct ». The information « no
rejection » from the dust sensor is 0 when there’s no dust emission.
-
If choice « REVERSE (1=OK) » : the type of the input is « reverse ». The information « no
rejection » from the dust sensor is 1 when there’s no dust emission.
Remark: in case of rejection control with a SPX50 sensor, the input type is « REVERSE (1=OK) ».
- Place the arrow on DUST INPUT TYPE and press the
button and the following display appears:
Note: Protected by code! appears if protection is activated.
To change the choice, use
buttons and press the button to store the choice and return to select
menu.
Summary of Contents for SFX+NETWORK
Page 21: ...Technical Data Sheet FI 72 0239 0320E Page 21 108 SIGNALLING...
Page 22: ...Technical Data Sheet FI 72 0239 0320E Page 22 108 CONNECTIONS CONNECTION EXAMPLE...
Page 24: ...Technical Data Sheet FI 72 0239 0320E Page 24 108 CONNECTIONS CONNECTION EXAMPLE...
Page 26: ...Technical Data Sheet FI 72 0239 0320E Page 26 108 CONNECTIONS CONNECTION EXAMPLE...
Page 28: ...Technical Data Sheet FI 72 0239 0320E Page 28 108 CONNECTIONS CONNECTION EXAMPLE...
Page 31: ...Technical Data Sheet FI 72 0239 0320E Page 31 108 CONNECTIONS CONNECTION EXAMPLE...
Page 34: ...Technical Data Sheet FI 72 0239 0320E Page 34 108 CONNECTIONS...
Page 37: ...Technical Data Sheet FI 72 0239 0320E Page 37 108 SFX MODULE POWER CONSUMPTION...
Page 38: ...Technical Data Sheet FI 72 0239 0320E Page 38 108...
Page 85: ...Technical Data Sheet FI 72 0239 0320E Page 85 108...