38
|
MAGIQTOUCH & MAGIQCOOL MODELS
Refit the pad frames by locating the bottom
edge in the tank groove, then push the top into
the lid.
ILL976-D
REFITTING THE PAD FRAMES FOR
BRAEMAR LCQI / LCQ / LCS / BMQ &
COOLAIR CPQ EVAPORATIVE COOLER
Component
Part No.
Watts
Total Max
Amps
Fan Motor
(Variable)
116907
340W
2.2
116914
430W
3.5
116921
600W
4.5
116938
950W
6.3
Component
Part No. Voltage
Ohms
Tornado
095806
240Vac
122 ±6
Drain valve
115986
12VDC
Solenoid valve
865607
12VDC
19.2±10%
Cooler
Electronics Box
116341
Solenoid Cable
865614
Water
Management
Probe
865621
QUICK REFERENCE GUIDE
BRAEMAR LCQI EVAPORATIVE
COOLER
cont
• Clean the metal probes
• Set the multimeter to ohms mode
• Pin 1 - Blue wire = approx. 0 (zero) ohms
• Pin 2 - Black wire = approx. 0 (zero) ohms
• * Pin 3 - Brown wire = approx 0 (zero) ohms
(3 prong probes only)
# A reading of 5 ohms or greater indicates
faulty probes.
* The brown wire (Pin 3) is not connected on 2
prong probes.
If the probe continues to fault, check between
the contacts to ensure there are no short
circuits.
PIN 1 (BLUE)
PIN 2 (BLACK)
PIN 3 (BROWN)
PIN 4 (EMPTY)
0.00
+
-
ILL2232-A
Pin 1
Pin 2
WATER SALINITY PROBE TESTING
NOTE:
The Salinity Probe plug connector for
LCQI coolers differs to the EXQ/LCQ, but the
wire colours and pin-outs are identical.