SEELEY INTERNATIONAL
- SERVICE GUIDE
|
23
ILL1660-A
Colour Flash
Indicates
No
glow
No power or a failure has
occurred. (Check power
supply to cooler including
isolating switch, circuit
breaker and plug and
socket connection in the
roof space)
Green
Every 2 sec Normal Operation
Red
1 Flash
Fault Code #1
Communication Failure
2 Flashes
*Fault Code #2
Failure to detect water at
probes within 20 mins.
4 Flashes
*Fault Code #4
Failure to clear probes
during drain within 20 mins.
9 Flashes
Fault Code #9
Incorrect Supply Frequency.
ILL1661-A
SALINITY LED
The bottom LED is red only and displays
salinity setting information for evaporative
coolers installed. Parameters are set by
MagIQtouch or MagIQcool wall controllers.
Refer to pages 17 or 21.
BREEZAIR EXQ / EZQ / EXS
EVAPORATIVE COOLER
cont
Sal Flash
Indicates
OFF
Not Applicable
1 Flash
WaterMiser
®
salinity is below the
set point.
2 Flash
WaterMiser
®
salinity is above the
set point.
3 Flash
The Salinity Control Method is set
for Timed Drain
4 Flash
Bleed Tray - No Drain Valve.
5 Flash
Thermostatic Control (no Water)
operation set.
Continuously
on
(When probes
immersed in
water)
Water not detected. The probes
are immersed in water but are
open circuit, or measured salinity
is less than 20µs/cm (the water
has very little salt content).
Continuously
on
(No water in
tank)
WaterMiser
®
/ Drain Valve option
is active
DIAGNOSTIC LED
The top LED glows green or red acting as a
diagnostic indicator. If the top LED is double
flashing green, everything is ok, this is normal
operation.
Salinity LED Indication for evaporative coolers
fitted with drain valves.
Sal Flash
Controller Salinity Setting
5 Flash
Salinity Control set
5 Flash
Timed Drain
4 Flash
The Salinity Control method is set
for continuous bleed
(bleed tray used)
5 Flash
Thermostatic Control No Water
(no water) operation
Salinity LED Indication for evaporative coolers
fitted with bleed trays and shorting links only.
*FAULT CODE 02 (2 Red Flashes)
Failure to detect water at probes within 20
minutes
*FAULT CODE 04 (4 Red Flashes)
Failure to clear probes during drain within 20
minutes
Refer to section
troubleshooting these fault codes.