SEELEY INTERNATIONAL
- SERVICE GUIDE
|
3
Contents
Qty Description
1
MaglQtouch Air Sensor
1
Communication Cable (20m)
2
Long Screws
2
Short Screws
2
Wall plugs
ILL1804-A
MAGIQTOUCH AIR SENSOR
The MagIQtouch Air Sensor is an optional
extra product which allows more flexibility with
where the MagIQtouch controller is mounted.
Each controller has a temperature & humidity
sensor mounted inside it which dictates how
the cooler operates. In the past, this has
restricted the locations where the controller
could be mounted for successful operation of
the cooler.
This optional Air Sensor allows the controller
to be mounted in a location not ideal for
temperature sensing (e.g. cupboard, hallway,
etc.). The installer can set up the MagIQtouch
controller to take temperature and humidity
readings from this Air Sensor and run the
cooler accordingly.
Details of the MagIQtouch Air Sensor kit are as
follows:
094328
MagIQtouch Air Sensor
MOUNTING LOCATION
The Air Sensor will be used instead of the
MagIQtouch controller for temperature sensing.
Follow the mounting location instructions in the
MagIQtouch controller section.
MOUNTING OPTIONS
Screw Boss Mounting
If permanently fixing the sensor, pull off the
front panel to expose the 2 screw bosses
inside.
Keyhole Mounting
If using the keyhole mounting method, first
remove the break-out pieces using a small
screw driver to lever upwards. The piece can
then be pulled out.
Important!
Be careful not damage the
electronics board inside the sensor when
removing the break-outs. Do not punch
inwards, but twist and pull out!
ILL1810-A
ILL1811-A