SEELEY INTERNATIONAL
- SERVICE GUIDE
|
37
BRAEMAR LCQI EVAPORATIVE
COOLER
cont
Step 12 Reconnecting mains power
Reinstate mains power supply to cooler at the
site’s electrical switchboard.
Step 13 Test the cooler
Test the cooler for correct operation at the wall
control.
Step 8 Refitting the fan
Locate the set screw on the fan to the dimple
on the motor shaft. The flat on the motor
shaft can be used as a visual indicator during
alignment as this is directly opposite the dimple
location.
Step 9 Refitting the motor cable tether
Turn the venturi assembly over and replace
the motor cable tether, securing it with the two
screws. Attach the clip-on ferrite across both
motor cables then cable-tie the cables to the
motor cable tether.
Step 10 Cooler assembly
Refit the venturi assembly into the tank. The
venturi will only sit correctly in one orientation
in the tank. The long ribs on the side of the
venturi must align with the slots on the tank
(Fig. 5).
Step 11 Motor to control box connection
Plug the replacement motor leads into
the electronics module (Fig. 6). Refit the
electronics module to the tank, replace screw
to secure. Turn the cooler’s electronic module
to the “I” (on) position.
ILL2119-A
DRAIN
MOTOR
CONTROL
WATER
PROBE
PUMP
SOLENOID
WALL CONTROL
DIAGNOSTIC
LEDS
FUSE
MAINS
CONNECTOR
MOTOR
560885
(UNDERSIDE OF ELECTRONICS MODULE)
ALIGN SET SCREW WITH
SHAFT DIMPLE
FLAT OPPOSITE
DIMPLE CAN BE
USED FOR
ORIENTATION
LOCATE LONG
RIB TO TANK SLOT
TANK SLOT
Fig. 4
Fig. 5
Fig. 6