Sensors
38
09.00 | NSR mini 100 / PKL mini 100 | Assembly and Operating Manual | en |
0489056
Assembly and Setup of the IN 50
Technical data:
Voltage:
10 – 30 V DC
Ripple:
≤ 15%
Max. current on contact:
200 mA, short-circuit-proof
Switching hysteresis:
≤ 15% of the nominal switching distance
Temperature range:
– 25°C to + 70°C
Switching frequency approx.:
1000 Hz
Voltage drop (max. load):
1.5 V
Protection class in accordance with DIN
60529:
IP 67*
* for the cylindrical connector only when screwed on
The IN 50 inductive proximity switch can be used to monitor the
presence of a pallet in the quick-change pallet system (see Fig.
"Mounting of the inductive proximity switch").
To do this, remove the set-screw (item 33) on the robot coupling
and screw in the proximity switch. Set the switching point so that
the proximity switch switches when the pallet is present. Secure
the IN 50 with the counter nut and test the function.