Part Number:- IM-018 

                                                                                  DATE: 20/1/17    REV: A 

 
 

      

 

 

 
 

 

 
 
 

KH14 

– SELF SERVE HOT FOOD 

INSTALLATION MANUAL: IM-018 

 

Standard versions

 

The following models are covered by this Manual 

 

KH14 

 
 

 
 

 

66 Glendenning Road, Glendenning NSW 2761

 

PO Box 42 Doonside NSW 2767

 

t: +61 2 8805 0400 

f: +61 2 9675 2897 

 

 

Summary of Contents for KH14

Page 1: ... REV A KH14 SELF SERVE HOT FOOD INSTALLATION MANUAL IM 018 Standard versions The following models are covered by this Manual KH14 66 Glendenning Road Glendenning NSW 2761 PO Box 42 Doonside NSW 2767 t 61 2 8805 0400 f 61 2 9675 2897 ...

Page 2: ...evelling 5 Attaching kick plates 8 Connecting power supply 9 Installing sensor probes 9 Mounting fixtures 10 Commissioning 11 Cleaning case 11 Starting up 11 Start up checks 11 Decommissioning 11 Disposal 11 Operation 12 Loading Merchandise 12 Cleaning and Maintenance 12 Daily Checks 12 Cleaning 13 Important Notes 13 Cleaning Procedure 13 Six Monthly Maintenance 14 Operation Servicing 14 Troublesh...

Page 3: ...amage to drainage outlets and electrical equipment mounted under or at the rear of cases CAUTION This symbol indicates electrical safety must be concerned WARNING Leave enough space to install the system The space requirement will be instructed in Pre installation section Before installing the system make sure the power source is accessible to the cases array All the power source has to be properl...

Page 4: ... KH14 SELF SERVE HOT FOOD _________________________________________________________________________________________________________________________ Page 3 Hussmann Case Services Dimensions Fig 1 Service layout standard depth case ...

Page 5: ...act your Hussmann Representative Handling and Transporting cases Case dimensions can be found in the product engineering data sheets This manual is a guide only Always refer to the latest case information available from Hussmann Customer Service Always ensure that the moving device is of a suitable type and has sufficient lifting capacity for the case weight and dimension Always lift cases from th...

Page 6: ...lling Each case has a unique identification number as follows Job no Line up no Case sequence no within line up Example 106076 42 4 identifies this case in the 4th sequence of the line 42 for the job 106076 As well as on the packaging the case identification number appears as a serial number on the rating plate most commonly located on the ceiling panel left hand end of the case refer to Fig 2 and...

Page 7: ...e is not level determine where the highest point of the plinth is and position the case allocated to this position first 3 Adjust the case height using the adjustable feet if fitted or metal shims do NOT use timber to ensure the case is level to within 1 5mm from front to back and side to side and chassis of case is NOT twisted Maximum 25mm adjustment Fig 4 Levelling feet adjustment NOTE It is imp...

Page 8: ...________________________________________________ Page 7 Hussmann Fig 5 Case Levelling Fig 6 Case twisting Make sure case is level Front to Back 1 5mm Side to Side 1 5mm Make sure all adjusting feet NOT just the ones at the end of the case are adjusted firmly to ensure case does not sag Make sure Chassis of case is NOT TWISTED ...

Page 9: ... once installation is complete and drains checked for water leaks Front Panel 1 Attached front panel and align with front skid rail refer figure 7 2 Push back panel into and over slot to clip in position 3 Screw panel into side bracket 4 Check front panel is securely in position Fig 7 Attached front panel Back Panel 1 Attached back panel and align with back skid rail refer figure 8 2 Push back pan...

Page 10: ...connect any other appliance using this source Size the cable according to AS3008 or relevant local standards For power rating please refer to product engineering datasheet for details Ensure the appliance is properly grounded earthed Installing Sensor Probes The KH14 range or cases have the probes pre fitted at the factory Probe location as per Fig 9 CAUTION Refer to relevant State or Territory le...

Page 11: ..._______________________________________________________________________________ Page 10 Hussmann CAUTION Do not walk or sit on cases Mounting fixtures Replace racks and shelves etc as necessary to store requirements NOTE Incorrect pan and display tag configurations may compromise case performance ...

Page 12: ...tion of RCD if fitted by Licensed Person 3 Turn case power on Start up checks by qualified persons only 1 Check that all lights and light RCDs if installed are working correctly 2 Check the thermostat is set correctly If installed 3 Approximately 2 hours after start up check that the case is at correct operating temperature refer the Product Engineering Data Decommissioning Plan and risk assess th...

Page 13: ...aily Checks If an alarm system is not part of the refrigeration installation the temperature of each case should be checked on a daily basis via the thermometer that may be located inside the product area or via another reliable method The case temperature should be in the range of 60 C 65 C when stabilised Up to three separate readings may have to be taken to ensure all the case temperature aren ...

Page 14: ...er faster than the waste outlet drain can drain it Cleaning Procedure 1 Turn off power Remove stock CAUTION If case fan power is not isolated then staff should wear hair nets and no jewellery or lose clothing The fan is protected by wire grill but the possibility exists for items to be caught 2 Remove all price tickets and any foreign materials from the case 3 Clean glass or mirrored surfaces with...

Page 15: ...base of the case 3 Check that all case panels glass and trims are secure and undamaged 4 Check for rust or paint damage 5 Clean the air grilles on the cases 6 Ensure all cable connections including screw terminals earth leads and straps are secure 7 Ensure insulation to all electrical components including fan if any controls earth terminals and lights are sound 8 Carry out electrical safety tests ...

Page 16: ...nditioner operation Power Supply fault operating at inappropriate settings or conditions Check power supply and settings Case shelf arrangement has been deviated significantly from original specified setup Re do the shelf arrangement as per the original specification Doors are not closed Ensure doors are kept closed None of above Contact Hussmann ISSUE POSSIBLE REASON REMEDIAL ACTIONS LAMP are not...

Page 17: ..._________________________________________________________________________________________________ Page 16 Hussmann Appendixes Appendix 1 Wiring diagrams Supplied with each case Appendix 2 Product Engineering Datasheet Supplied with each case Appendix 3 Setting Table Part of PED ...

Page 18: ...y become pinched or crushed during the positioning of base trays shelves stock Staff must be trained in the correct procedures for setting up cases and ergonomic practices Slipping Drain may leak or become blocked causing water spillage Visual Inspection and regular maintenance Request service call when necessary Cuts and stabbing Potential for cuts caused by damaged or missing parts Visual Inspec...

Page 19: ... 40 125 degree oC Accuracy range 0 3 oC within 40 100 oC 1 oC out of that range Relay outputs 16 4 A 240Vac Power supply 230Vac 10 50 60Hz 2W Operation condition 10 50 oC 15 80 RH Main Setting Index DESCRIPTION SCL Readout scale Caution when changing SCL it is necessary to re configure other parameters below SPL Minimum limit for 1SP setpoint SPH Maximum limit for 1SP setpoint 1SP Case setpoint 1H...

Page 20: ...________ Page 19 Hussmann Appendix 6 Warranty The information in this manual is for Qualified Persons Only It is NOT an Installation Guide for NON Qualified Persons To obtain warranty information or other support contact your nearest Hussmann representative Please include the following Customer site location Cabinet model serial number of product Reason for warranty ...