Assembly
18
09.00 | NSR mini 100 / PKL mini 100 | Assembly and Operating Manual | en |
0489056
Two mounting screws are used as fitting screws for positioning the
robot coupling precisely on the necessary robot flange. Precise
alignment and positioning of the quick-change pallet system
requires that the fitting bores Ø 8 H7 on the opposite side are
precisely positioned in the mounting position.
Cylindrical screw (3x)
Fitting screw for
centering in middle axis
Fitting screw for
aligning diagonally
offset
Customer-specific robot flange
Sensor cables
Mounting
The air connection takes place via the side M5 coupling holes as
standard. Straight or angled pneumatic screw connections can be
fitted for the air supply.