23
24
8. Function Setting
1. Hold (MENU button) for more than two seconds while power is on.
2. Select menu in Main menu with (ON/OFF, ZERO button), and go to
Sub menu with (PEAK button). (Some menu doesn’t have Sub menu.)
3. Select menu in Sub menu with (ON/OFF, ZERO button), and go to
Setting menu with (SEND button).
(Go back to Main menu with (PEAK button.)
4. Select menu in Setting menu with (ON/OFF, ZERO button), and
enter the setting with (MENU button).
(The setting can be saved only when entered with MENU button.)
5. The display automatically goes back to Sub menu after entering.
Go back to Main menu with (SEND button).
6. Push to show ‘Exit Menu’ and go back to measurement-ready
display with (MENU button).
* Push and hold (MENU button) more than 2 seconds for the same action.
Set sub comparator value to
judge whether displayed
value reaches the set value.
The result is output to
external equipment.
OFF: Displayed value
<
No.1 or No.2 setpoint.
ON: No.1 or No.2 setpoint
≦
Displayed value
This function is only for
output.
Function Setting (Program Menu)
Main menu
Sub menu
Setting menu
Description
High
+/- [0000 to 9999]
+/- [0000 to 9999]
High / Low
Setpoints
Low
Set Hi and Low values. LED
and output signal show
whether the measurement
value is below, within, or
above the set values.
-NG: Displayed value
<
Low
setpoint
OK: Low setpoint
≦
Displayed value
≦
Hi
setpoint
+NG: Displayed value
>
Hi
setpoint
High / Low
Output
Value no.2
Value no.1
+/- [0000 to 9999]
+/- [0000 to 9999]
Initial setting
+Capacity
-Capacity
0000
0000
Valid model
ZTA/ZTS
eZT
ZTA
eZT