SAFETY CHAIN KNA CONTACT OVERBRIDGING ACTIVATION
The overbridging of the safety circuit contact at the car emergency exit (for
example, used in fire operation Korea) wasn't successful.
C1:SIAP PCB defect (for example, relays simulating door zone
(PHS/PHS1) defect)
A1:Replace SIAP board
3506
SAFETY CHAIN KNA CONTACT OVERBRIDGING LOST
The overbridging of the safety circuit contact at the car emergency exit (for
example, used in fire operation Korea) was lost.
C1:SIAP PCB defect (for example, relays simulating door zone
(PHS/PHS1) defect)
A1:Replace SIAP board
3507
SAFETY CHAIN KNA CONTACT OVERBRIDGING DEACTIVATION
The cancellation of the overbridging of the safety circuit contact at the car
emergency exit (for example, used in fire operation Korea) wasn't successful.
C1:SIAP PCB defect (for example, relays simulating door zone
(PHS/PHS1) defect)
A1:Replace SIAP board
3508
SAFETY CHAIN KNA CONTACT UNEXPECTED OVERBRIDGING
An unexpected overbridging of the safety circuit contact at the car emergency
exit has occurred.
C1:SIAP PCB defect (for example, relays simulating door zone
(PHS/PHS1) defect)
A1:Replace SIAP board
3509
SAFETY CHAIN SIM DOORZONE CONTACT OVERBRIDGING
ACTIVATION UNSUCCESSFUL
The overbridging of the door safety circuit contacts, allowing to travel the car
with opened doors (for example, used in fire operation Korea) wasn't
successful.
C1:Wiring of door zone simulation bad
A1:Check connections between SUET board and SIAP board
C2:SIAP PCB defect (for example, relays simulating door zone
(PHS/PHS1) defect)
A2:Replace SIAP board
C3:Door safety circuit overbridging failed
A3:Check errors 0338 for cause and actions
3510
SAFETY CHAIN SIM DOORZONE CONTACT OVERBRIDGING LOST
The overbridging of the door safety circuit contacts, allowing to travel the car
with opened doors (for example, used in fire operation Korea) was lost.
C1:Wiring of door zone simulation bad
A1:Check connections between SUET board and SIAP board
C2:SIAP PCB defect (for example, relays simulating door zone
(PHS/PHS1) defect)
A2:Replace SIAP board
C3:Door safety circuit overbridging lost
A3:Check errors 0339 for cause and actions
Code