Schindler 3100/3300/6300
J 43402603 / 01
228/269
Copyright © 2017 INVENTIO AG
Door Panel
Alignment T2
Synchronization Check for T2-EU/NA [42121; 13.12.2011]
No
Step
1
Door opened, check the fast door panel (8) is aligned to the jamb (6).
2
If the fast door panel (8) is not aligned with the jamb (6), adjust it using the set
screw (1).
3
Door opened, check the slow door panel (7) is aligned to the jamb (6).
4
If the slow door panel (7) is not aligned with the jamb (6), adjust it by loosening
the M6 x 16 bolt (4) to slacken the synchronization cable (5).
1
Set screw
2
Closing bumper
3
Clamp
4
M6 x 16 bolt
5
Synchronization cable
6
Jamb
7
Slow door panel
8
Fast door panel
9
Alignment tool (spirit level or other)
1
2
3
4
5
6
7
8
9