Schindler 3100/3300/6300
J 43402603 / 01
146/269
Copyright © 2017 INVENTIO AG
2416
FC PROXY WARNING GENERIC LOGICAL ERROR
C1:EC application (Internal) error. Collects the rest of unmentioned
errors.
2417
FC PROXY WARNING HIGH LOAD UNBALANCE
C1:EC application (Internal) error.
2418
FC PROXY WARNING DRIVE BECAME UNAVAILABLE
C1:Drive (FC) became unavailable (for example, command. lost or other
error happened)
A1:Check FC parameters. Restart system and reset FC errors. Change FC
2419
FC PROXY WARNING DRIVE PHASE BECAME UNKNOWN
C1:Drive (FC) state transition inconsistency or communication lost cause
the "Drive-phase" to be unknown.
A1:Check CAN bus.
2420
FC PROXY WARNING UNKNOWN FC ERROR RECEIVED
C1:Unknown FC error received
A1:Version compatibility?
2421
FC PROXY WARNING UNKNOWN FC ALARM RECEIVED
C1:Unknown FC alarm received.
A1:Version compatibility?
2422
FC PROXY WARNING RECOVER FROM ERROR LOGIC
C1:EC application (Internal) error.
2423
FC CMD STOP TIMEOUT
C1:Drive (FC) does not confirm the stopping request.
A1:Check CAN cable. Check CAN cable termination
C2:The EC sends a move command to the FC and the FC does not
answer.
A2:Check if FC is running
2424
FC PROXY WARNING STATIC MOVE RQST WHILE NOT IN STAND BY
C1:EC request a move while drive was not in standby.
A1:Reset EC.Report repeated occurrences.
2425
FC PROXY WARNING DYNAMIC MOVE RQST WHILE DECELEREATING
C1:EC requested a dynamic move while drive was decelerating.
A1:Reset EC. Report repeated occurrences.
2426
FC PROXY WARNING DYNAMIC MOVE RQST WHILE IN STAND BY
C1:EC requested a dynamic move while drive was in standby (=not
dynamic).
A1:Reset EC. Report repeated occurrences.
2427
FC PROXY WARNING FC SW VERSION UNKNOWN YET
2428
FC PROXY WARNING FC HARDWARE VERSION UNKNOWN YET
2429
FC PROXY PARAMETER DOWNLOAD FAILED
C1:Drive (FC) reports a parameter download failure
A1:Check FC parameter values
Code
Frequency Converter Alarming Message