Installation
Technical modifications reserved
40
Edition 2004
Check for the presence of the signal
(10V)
(pin 3 -1 of the PC connector)
Replace the DSP board in the P.C.
Check the connection wire between the
rack and Resonator
7) No aiming red laser
-Display signals READY
-Status led Orange
No power
Replace the DL connection wire
Make sure the cooling air circulates
freely
Make sure the fans are running correctly
Check the ambient temperature
( max.35 °C )
Turn the switch to OFF, wait 10s and turn
to ON.
8.a) The laser stops emitting
-Display in alarm
-Status led Green
Temperature protection tripped
with presence of Alarm
“MAX TEMPERATURE ALARM”
Contact the Call Centre
Make sure the cooling air circulates
freely
Make sure the fans are running correctly
8.b) The laser stops emitting
-Display in alarm
-Status led Green
Temperature protection tripped
with presence of Alarm
“M/S HIGH DIODE TEMP”
Make sure the radiator is clean
Make sure the cooling air circulates
freely
Make sure the fans are running correctly
8.c) The laser stops emitting
-Display in alarm
-Status led Green
Temperature protection tripped
with presence of Alarm
“M/S INCORRECT DIODE TEMP”
Make sure the ambient temperature is
above 5 °C and below 35°C
Check the output optical power
9) Laser emission is irregular
-Display signals READY
-Status led Red
Variation of the output optical
power
Check the level signal
Check the hours of operation
10) Laser emission is low
-Display signals READY
-Status led Red
Decrease of the output optical
power
Contact the Call Centre
Check the connections of the TS and STS
wires
11) The scanner head does not
work
No power or no signal
Replace the DSP board