Schilling Marking Systems GmbH
In Grubenäcker 1 DE-78532 Tuttlingen
+49 (0)7461 9472-0
+49 (0)7461 9472-20
www.schilling-marking.de
MegaLight
Installation
Technical modifications reserved
30
Edition 2004
Preliminary Commissioning (Safety instructions)
WARNING:
When commissioning and before the laser radiation protection barriers have been
positioned, always wear goggles with an optical density OD of 5 or higher, which
are certified as in conformity with both wavelengths of 808nm and 1064nm.
Always avoid direct viewing of the laser beam. No goggles are able to withstand
direct laser radiation for long.
WARNING:
The installation, use or maintenance of the system in a manner other than that
described in this manual may cause dangerous exposure to laser radiation or
electrical risk.
Commissioning
Before starting the start-up procedure make sure the following preliminary operations have
been carried out:
•
Make sure the operating area is free from clutter.
•
Make sure there is enough free space in front of and behind the power supply box, to
ensure cooling air flow.
•
Make sure that the plug is correctly inserted.
•
Make sure all the electrical connection have been correctly effected.
•
Make sure the optical fibre is connected to the power supply box and Resonator.
•
Make sure the protective cover of the scanner head lens has been removed.
•
Make sure the optical path of the laser beam terminates at the end of its useful path.
Start-up procedure (Hardware)
1.
Put the main switch MS in the closed position (I) and make sure the following events
occur at the same time:
•
the display goes on
•
the fans start
2.
Give the START command, using an impulse command to close the contact between pin
04 and 12 of the COMMAND BOX connector (7) located on the rear Management Panel
of the power supply box (see Appendix B. Wiring and connection diagrams). Make sure
that the following event occurs:
•
GREEN led on POWER ON condition
3.
After around 1 second, if the laser diode temperature is correct, the device is ready to
operate and goes to the Stand-by condition. Make sure that the following events occur:
•
ORANGE led on: STANDBY condition
•
The aiming red diode appears at the output of the laser beam