Schilling Marking Systems GmbH
In Grubenäcker 1 DE-78532 Tuttlingen
+49 (0)7461 9472-0
+49 (0)7461 9472-20
www.schilling-marking.de
MegaLight
Installation
Technical modifications reserved
35
Edition 2004
•
ORANGE led on: STAND-BY condition
•
The aiming red diode appears on the beam
6.
Enable the ELECTRONIC SHUTTER using the STAND-BY / READY button and make sure
the following events occur:
•
RED led on: READY condition
•
The aiming red diode disappears from the beam
7.
If this occurs, temporarily remove the protections to access the work area.
8.
Adjust the focus of the laser and engraving parameters, following the instructions in the
Smartist4 Manual.
9.
Restore the protections, if they were removed earlier.
10.
Start engraving.
WARNING:
From this time on the source is enabled for emitting laser radiation from the
engraving head. Be careful not to expose yourself to optical risk.
Turning off
1.
Disable the ELECTRONIC SHUTTER using the STAND-BY / READY button and make sure
the following events occur:
•
ORANGE led on: STAND-BY condition
•
The aiming red diode appears on the beam
2.
Give the STOP command and make sure the following events occur:
•
GREEN led on POWER ON condition
•
The aiming red diode disappears from the beam
3.
Exit the Smartist4 engraving program.
4.
Put the main switch MS in the open position (
O
) .
5.
Replace the protective cover on the lens, located on the engraving head.
6.
Disconnect the device from the mains.
Replacing the lens
If it is necessary to replace the lens, proceed as follows:
1.
Make sure the main switch MS is in the OFF position (O ).
2.
Cap the lens with the specific lens supplied with the system.
3.