2.
Slide the optical fibre into the spring mounted grommet in the supplied back cover.
3.
On the Rear Management Panel of the power supply box, remove the protective sticker
and seal on the OPTICAL FIBER connector (10).
4.
Referring to Fig. 12: optical fibre connector, remove the protective cap (1) from the
optical fibre connector, by unscrewing nut (4).
5.
Insert the optical fibre connector in the OPTICAL FIBER connector (10) of the power
supply box:
- gently place the optical fibre connector on the fibre socket
- carefully insert the optical fibre connector, making absolutely certain that the
optical surface of the fibre connector (2) does not come into contact with any
other surface.
WARNING:
The operation for inserting the fibre needs to be carried out very carefully.
Absolutely avoid letting the optical surface of the fibre connector come into
contact with any other surface.
Contact of the fibre optical surface with any other surface may damage it.
6.
Make sure the mechanical supports (3) on the male/female connectors are in the
correct position.
7.
Screw down nut (4) in the OPTICAL FIBER connector of the power supply box.
8.
Screw down the rear cover on the power supply box.
The procedure to connect the optical fibre to the Resonator is as follows:
1.
Make sure the main switch MS is in the OFF position (O ).
WARNING:
Laser radiation may leak from the free end of the optical fibre. Never work on
the device with the power on.
Operating with the rack power on may cause serious optical risk.
2.
Remove the rear cove of the resonator, by unscrewing the three screws (see Appendix
A. Technical specifications).
Picture 12: Optical fiber connector