Individual Protection Devices (I.P.D.)
Before using the laser system, the Operator must be instructed on the risks involved with
using the laser system and the necessity of wearing protective goggles during all operations
which require accessing the radiation.
The Nominal Ocular Hazard Distance (NOHD) for the Megalight™ is equal to approximately
15m in the case of direct or reflected radiation and 0.5m in the case of scattered radiation.
Warning: the goggles are not sufficient for protecting the eye from direct laser radiation.
Before using the laser system, the Operator must be instructed on the risks associated with
using the device primarily resulting from the possibility of igniting flammable material, when
hit by laser radiation, such as volatile substances, resins or plastics.
The interaction of the laser beam with organic or inorganic compounds causes the formation of
fumes and vapours, which may be harmful or toxic.
N.B.: Make sure the personnel assigned to using the System have read this manual and the
Laser Safety Manual before using the engraving system.
Daily use by an Operator
The Operator is required to carry out the following preliminary tests before each use of the
laser device:
•
Make sure the operating area is free from clutter.
•
Make sure there is enough free space in front of and behind the power supply box, to
ensure cooling air flow.
•
Make sure that the plug is correctly inserted.
•
Make sure all the electrical connection have been correctly positioned.
•
Make sure the optical fibre is correctly connected to the power supply box and
Resonator.
•
Make sure the protective cover of the lens, located on the engraving head, has been
removed.
Turning on
The Operator must carry out the procedure described below to turn on the system:
1.
Put the main switch MS on the CLOSED position (
I
)
2.
Start the P.C.
3.
Start the Smartist4 engraving software (see the specific manual).
4.
If necessary, wear the specific individual protection devices
5.
Start the device by giving the START command and making sure the following events
occur: