Installation procedure
Environmental requirements
Before installing the Megalight™ engraving system, make sure that:
•
The system is situated in a controlled area dedicated to laser processing.
•
Until the system has been installed with all the safety devices and until it correct
operation has been tested, the installer must have the laser area guarded and not let
unauthorized personnel access the area.
•
The System is positioned on a stationary surface with no vibration. In order to prevent
distortions in the engraving, install the head and the piece to be worked on the same
support, so that the piece is not subject to vibration during processing.
•
To adequately house the wires and standard optical fibre equipped with the System
(max. length 3m), the power supply box and laser head must be positioned at less than
2m. Longer wires and optical fibre can be supplied upon specific request.
•
Leave a free space of at least 10 cm in front of and behind the power supply box to
ensure the necessary flow of cooling air.
•
Do not install the System in an excessively dirty area, in the presence of dust, oil,
chemicals, fumes or excessive humidity.
•
Do not install the system in a place where the ambient temperature falls below 15 °C
or can rise above 35°C.
•
Do not install the System in a place where the relative humidity often exceeds 80%.
•
Do not install the System in a place with an altitude over 1500m.
(see Appendix A: Technical specifications)
N.B.: Sudden and often variations in temperature can cause condensation on the surfaces of
the lens with the deposit of dust, which can damage optical parts.
1. Connection to the mains
The required mains is the Public mains protected and dimensioned with the following
requirements:
•
Single phase voltage P+N+PE 90-240Vac (±10%)
•
Mains frequency 50-60Hz
•
Harmonic distortion <10%
•
Interruptions <3ms
•
Max absorbed power 400W
WARNING:
Do not work on the electrical part if you are not an expert!
Do not remove protection devices.
Do not replace the fuses with ones of another calibre and type.