15
4. Installation as insert
Installation into a non combustible construction. Existing or new build.
Options:
•
Vertical direct vent system (co-linear).
•
Residential
•
Straight or corner placement.
•
Bedroom approved.
4.1. Insert placement requirements
•
The Insert must be installed on a level surface capable of supporting the insert and vent system.
•
Due to the high temperature of the insert, it should be located out of traffic and away from furniture and
draperies. The insert must be placed so no combustibles are within, or can swing within 36” of the front of
the insert (e.g. drapers, doors).
NOTE: We do not recommend the use of wallpaper next to this insert. Over time, radiant heat may cause the wallpa-
per to shrink, or may adversely affect the binders in the wallpaper adhesive.