24
5.4. Installation hints
•
If converting to LP, convert the ZC-fireplace prior to installation.
•
Install the logs last because they are fragile.
•
Fumes and smoke from the paint curing and oil burning off the steel may occur the firs time you start this
ZC-fireplace. This is normal. We recommend you open windows to vent the room.
5.5. ZC-fireplace clearances
•
Cover door to sidewall = 3”
•
Cover door to mantel = 21”
•
Zero clearance enclosure to unit front = 3 ½”
•
Zero clearance enclosure to unit back = 5”
•
Unit bottom to floor = 3/8”
•
Top of unit to zero clearance enclosure ceiling = 56”
Be sure to mount the six standoffs as shown below. This assures the correct clearances to top and sides.