47
7.3. Lighting instructions
1.
STOP! Read the safety information on page 46 before proceeding.
2.
Set the thermostat to lowest setting (If applicable).
3.
For an insert / ZC-fireplace that utilizes an external electrical supply: Turn off all electric power to the insert /
ZC-fireplace. (Room air blower if applicable).
4.
Push the gas control knob in slightly and turn it clockwise to the “OFF” position. NOTE: The knob will not
turn from “ON” to “OFF” unless the knob is depressed slightly. Do not force.
5.
Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor, if you smell gas,
STOP! Follow paragraph 3 in the safety information on page 46.
6.
Turn gas control knob counterclockwise to the “PILOT” position.
7.
Press the knob in and hold.
8.
Immediately press the igniter button repeatedly until the pilot is lit. WARNING: If the pilot does not light
after 30 seconds, release the knob and call your insert / ZC-fireplace dealer for service. See fig 10 on
previous page for pilot burner location.
9.
Keep the gas control knob depressed for 30 seconds once the pilot is lit.
10.
Release the gas control knob. If the pilot goes out. Repeat step 7, 8 and 9. If the knob does not pop up when
released, stop and immediately call your insert / ZC-fireplace dealer or gas supplier for service. If the pilot
will not stay lit after several tries, turn the gas control knob to “OFF” and call your insert / ZC-fireplace
dealer or gas supplier for service.
11.
Turn the gas control knob counterclockwise to “ON”.
12.
Turn on the electric power to the insert / ZC-fireplace. Blower (room air blower) on the insert / ZC-fireplace.
13.
Set the thermostat to desired setting (if applicable) or use the ON/OFF rocker switch or remote control to
operate the main burner.
Summary of Contents for 70 gas insert / ZC-fireplace
Page 20: ...20 4 4 Approved venting configurations for vertical terminations Left Damper Right damper...
Page 32: ...32 Left Damper Right damper...
Page 33: ...33 5 13 Approved venting configurations for vertical terminations...
Page 34: ...34 Left Damper Right damper...
Page 49: ...49...
Page 60: ...60 Use a 3 mm hexagon key and a 13 mm open end wrench...
Page 61: ...61 9 3 Wiring diagram for blower 120 Volt Diagram 4...
Page 64: ...64 11 Safety label...