48
7.4. To turn of gas to insert / ZC-fireplace
1.
Set the thermostat to lowest setting (if applicable).
2.
Turn off the blower (room air blower) on the insert / ZC-fireplace.
3.
Turn off the electric power to the insert / ZC-fireplace if service is to be performed.
4.
Push the gas control knob in slightly and turn it clockwise to the “OFF” position.
7.5. Starting the insert / ZC-fireplace for the first time
Fumes from the painted surfaces curing:
Burn the insert / ZC-fireplace at a medium setting for approximately one hour the first time. This will cure the painted
surfaces. Fumes from the paint curing and oil burning off the steel may occur. This is normal. We recommend you
open a window to vent the room.
Condensation:
Water may appear on the glass each time you start the insert / ZC-fireplace – this is normal.
Blue flames:
The flames will be blue when first started, after fifteen minutes the flames will turn to a more realistic yellow and
orange color.
Turning the insert / ZC-fireplace on and off
after the pilot has been started.
Warning: Do not place combustible items on top or directly in front of the insert / ZC-fireplace, even temporarily.
The operation thermostat may start the heater causing a combustible item to ignite.
Note:
If the insert / ZC-fireplace turns on and off frequently while using the thermostat function in the remote
control you may want to adjust the flame height down until it produces just enough heat needed.
7.6. Adjusting the flame height
Your insert / ZC-fireplace has an adjustable flame to tailor the look and heat output to your specific needs. It is ad-
justed by turning the middle dial on the gas control valve.
Use this switch to turn
the main burner on and
off manually
See the instructions included
with the remote for details on
operation
See the instructions
included with the remote
for changing the battery
Flame height
adjustment knob
Center mark
Turn counter-clockwise to adjust the flame higher, clockwise to lower
Summary of Contents for 70 gas insert / ZC-fireplace
Page 20: ...20 4 4 Approved venting configurations for vertical terminations Left Damper Right damper...
Page 32: ...32 Left Damper Right damper...
Page 33: ...33 5 13 Approved venting configurations for vertical terminations...
Page 34: ...34 Left Damper Right damper...
Page 49: ...49...
Page 60: ...60 Use a 3 mm hexagon key and a 13 mm open end wrench...
Page 61: ...61 9 3 Wiring diagram for blower 120 Volt Diagram 4...
Page 64: ...64 11 Safety label...