25
5.6. Mobile home requirements
When the ZC-fireplace is installed in a mobile home it must be bolted to the floor.
The ZC-fireplace, when installed, must be electrically grounded in accordance with local codes or, in the absence of
local codes, with the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22.1.
5.7. Floor protection requirements
When the ZC-fireplace is installed directly on carpeting, vinyl or other combustible material other than wood flooring
or a high pressure laminate wood floor, the ZC-fireplace must be installed on a metal or wood protection panel
extending the full width and depth of the ZC-fireplace (minimum 30x22
⅛
”). Furthermore the four adjustable feet’s
must be screwed out to 3/8” from the bottom of the ZC-fireplace. See Figure 8.
Figure 8
Summary of Contents for 70 gas insert / ZC-fireplace
Page 20: ...20 4 4 Approved venting configurations for vertical terminations Left Damper Right damper...
Page 32: ...32 Left Damper Right damper...
Page 33: ...33 5 13 Approved venting configurations for vertical terminations...
Page 34: ...34 Left Damper Right damper...
Page 49: ...49...
Page 60: ...60 Use a 3 mm hexagon key and a 13 mm open end wrench...
Page 61: ...61 9 3 Wiring diagram for blower 120 Volt Diagram 4...
Page 64: ...64 11 Safety label...