3. General specifications
3.1. Packing list
•
Base unit
•
Log set (consist of 4 pieces)
•
Hexagon keys, wrenches
•
Door with or without front glass
•
Coaxial or co-linear venting configuration
•
Remote control (optional)
3.2. Features
•
Works during power outages (millivolt system)
•
High efficiency
•
Optional thermostat or remote control with thermostat.
•
Built in blower for efficient heat distribution
•
Convenient operating controls
•
Variable rate heat output
•
Low maintenance
3.3. Heating specifications
Approximate heating capacity (in square ft.)*
500-1700 with blower, 500-1200 without.
Maximum
input
30000
BTU
Output range in BTU per hour
14700 to 21000
Steady state efficiency**
up to 71%
AFUE (without blower)
up to 70%
* Heating capacity will vary depending on the floor plan, degree of insulation, and the outside temperature.
** Efficiency rating is a product of thermal efficiency rating determined under continuous operation independent of
installed system.
3.4. Weight
120 lbs.
3.5. Electrical
Electrical specification for blower: 115 volt 60 Hz (66 watts on high).
3.6. Fuel
This insert / ZC-fireplace is shipped in natural gas (NG) configuration but may be converted to propane (LP) using a
LP conversion kit. The sticker on top of the gas control valve will verify the correct fuel.
3.7. Installation (for qualified installer only)
THIS INSERT / ZC-FIREPLACE MUST BE INSTALLED AND MAINTAINED BY A QUALIFIED
SERVICE AGENCY.
The installation and repair of this insert / ZC-fireplace must be done by a qualified service agency. Failure could result
in an unsafe or hazardous installation, which may result in a fire, explosion, property damage, personal injury or loss
of life.
This insert / ZC-fireplace should be inspected before use and at least annually. More frequent cleaning may be re-
quired due to excessive lint from carpeting, bedding material, etc. It is imperative that control compartments, burners
and circulating air passageways of the insert / ZC-fireplace be kept clean.
Summary of Contents for 70 gas insert / ZC-fireplace
Page 20: ...20 4 4 Approved venting configurations for vertical terminations Left Damper Right damper...
Page 32: ...32 Left Damper Right damper...
Page 33: ...33 5 13 Approved venting configurations for vertical terminations...
Page 34: ...34 Left Damper Right damper...
Page 49: ...49...
Page 60: ...60 Use a 3 mm hexagon key and a 13 mm open end wrench...
Page 61: ...61 9 3 Wiring diagram for blower 120 Volt Diagram 4...
Page 64: ...64 11 Safety label...