57
9. Optional equipment (for qualified installer only)
9.1. Conversion from NG to LP (for qualified installer only)
9.2. Conversion from LP to NG (for qualified installer only)
Caution:
Use only Krog Iversen (SCAN) original spare parts for conversion
Install the conversion kit prior to installing the gas line to ensure proper gas use.
The procedure for converting is the same in both occasions but there is a conversion kit for each way.
A
Lift the pilot
hood off the
pilot
assembly.
B
Use a hex wrench
to unscrew the orifice.
NOTE:
When re-attaching, this
pin lines up with the notch in
the pilot hood.
C
Remove the orifice and replace with the LP
orifice. Screw the orifice all the way in and
replace the pilot assembly.
Use a 4 mm hexagon key.
Orifice identification
LP (propane) orifice
35
NG (natural gas) orifice
62
A
Remove and discard the three
screws using a slotted
screwdriver of Torx T-20.
C
Install the LP regulator. Use the
screws included with the LP regulator.
Tighten to approximately 25 Lbs. torque.
B
Remove and discard the regulator,
diaphragm, spring and center post.
NOTE:
Make sure the regulator gasket is
correctly aligned before installation.
See the instruction included with the
conversion kit for further details
about the installation
Summary of Contents for 70 gas insert / ZC-fireplace
Page 20: ...20 4 4 Approved venting configurations for vertical terminations Left Damper Right damper...
Page 32: ...32 Left Damper Right damper...
Page 33: ...33 5 13 Approved venting configurations for vertical terminations...
Page 34: ...34 Left Damper Right damper...
Page 49: ...49...
Page 60: ...60 Use a 3 mm hexagon key and a 13 mm open end wrench...
Page 61: ...61 9 3 Wiring diagram for blower 120 Volt Diagram 4...
Page 64: ...64 11 Safety label...