W415-0098 / C / 04.19.06

INSTALLER: THESE INSTRUCTIONS MUST BE CONVEYED TO AND REMAIN WITH THE HOMEOWNER.

Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 4Y8 Canada • (705)721-1212 • fax(705)722-6031

www.napoleonfireplaces.com • [email protected]

GAS-FIRED STOVES

INSTALLATION AND OPERATION INSTRUCTIONS FOR:

VENTED GAS FIREPLACE HEATER

CERTIFIED UNDER CANADIAN AND AMERICAN NATIONAL STANDARDS, CSA 2.33, ANSI Z21.88 FOR VENTED GAS FIREPLACE HEATERS

WARNING:  If the information in these instructions is not followed exactly, a fire or

explosion may result causing property damage, personal injury or death.

FOR YOUR SAFETY

Do not store or use gasoline or other flammable vapours and liquids in the vicinity of

this or any other appliance.

WHAT TO DO IF YOU SMELL GAS:

•  Do not try to light any appliance.
•  Do not touch any electrical switch.
•  Do not use any phone in your building.

Installation and service must be performed by a qualified installer, service

agency or the gas supplier.

NATURAL GAS MODELS 

 

GDS 50-N

PROPANE GAS MODELS

  

GDS 50-P

NATURAL GAS MODEL

  

GS 50-N

PROPANE GAS MODEL

  

GS 50-P

CERTIFIED FOR CANADA AND UNITED STATES USING ANSI / CSA METHODS

•  Immediately call your gas supplier from a
neighbour's phone. Follow the gas supplier's
instructions.
•  If you cannot reach your gas supplier, call
the fire department.

Summary of Contents for GDS 50-N

Page 1: ...g property damage personal injury or death FOR YOUR SAFETY Do not store or use gasoline or other flammable vapours and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GA...

Page 2: ...ld be located out of traffic and away from furniture and draperies Clothing or other flammable material should not be placed on or near the stove Any safety screen or guard removed for servicing must...

Page 3: ...ver requires the prior approval of an authorized company official Labour costs to the account of to the account of to the account of to the account of to the account of NAPOLEON NAPOLEON NAPOLEON NAPO...

Page 4: ...og The appliance off valve must be a T handle gas cock The flexible connector must not be longer than 36 inches The appliance is not approved for installation in a bedroom or bathroom unless the unit...

Page 5: ...If possible you should choose a loca tion where the vent will pass through the house without cutting a floor or roof joist Provide adequate ventilation and combustion air Provide adequate accessibilit...

Page 6: ...rovide seals on the inner exhaust flue only the outer air intake joints must be sealed using a red high temperature silicone RTV This same sealant maybe used on both the inner exhaust and outer intake...

Page 7: ...tly closed windows Vertical clearance to ventilated soffit located above the terminal within a horizontal distance of 2 feet from the centerline of the terminal Clearance to unventilated soffit Cleara...

Page 8: ...f the initial 90 elbow The total run is 5 ft through the roof vertical rise 10 ft 90 elbow 5 ft horizontal run 20 ft total run Using the chart will determine that a 57 inch minimum vertical rise immed...

Page 9: ...ial A vent pipe shield will prevent any materials such as insu lation from filling up the 1 air space around the pipe FIGURE 15 Nail headers between the joist for extra sup port FIGURE13 FIGURE12 OR F...

Page 10: ...predetermined intervals to maintain a 1 1 4 air gap to the outer flex liner These spacers must not be removed FOR SAFE AND PROPER OPERA FOR SAFE AND PROPER OPERA FOR SAFE AND PROPER OPERA FOR SAFE AN...

Page 11: ...ws and seal 2 Install the 4 aluminum flexible liner to the stove Secure with 3 screws and flat washers Seal the joint and screw holes using Mill Pac high tem perature sealant not supplied 3 Run a bead...

Page 12: ...accept a standard matte black 7 stove pipe and the Napoleon decorative brass band standard with the GS150KT Both are available from your Napoleon dealer For ease of assembly a 7 telescoping stove pip...

Page 13: ...the terminal block into place as shown with the screw supplied FIGURE 28 5 Gently pull the two white spill switch wires to take up any slack Feed these wires down through the combustion air opening an...

Page 14: ...NT AIRINTAKESYSTEM L APPAREIL DOIT EVACUER SES GAZ EN UTILISANT L ENSEMBLE D EVACUATION PROPRE A NAPOLEON REFERER AU MANUEL D INSTALLATION DE PROPRIETAIRE POUR L EVACUATION PRECISE IL EST IMPORTANT DE...

Page 15: ...catch The door may now be safely opened To close the door repeat in reverse order There may be instances that require adjustment of the door latches To do this simply loosen the tighten the catch unti...

Page 16: ...e only certified PHAZERTM logs and charcoal embers available from your Napoleon Wolf Steel Ltd dealer 1 Place the 2 piece charcoal ember strip along the edge of the firebox 2 Place base log 1 between...

Page 17: ...low is at the burner before closing the door Allow several minutes 5 15 for the flame to stabi lize after ignition The purpose of the turbo burner is to increase heat output or BTUs of the unit and wi...

Page 18: ...artment FLAME ADJUSTMENT KNOB O T P I L L O I H T P I L O N O F F O PILOT ON OFF KNOB GAS KNOB A This fireplace is equipped with a pilot which must be lit by hand while following these instructions ex...

Page 19: ...ting the rubber grommets Replace the bracket blower assembly in the unit 6 Reconnect the two wires Hold the replacement gasket in place and reattach the relief door assembly Replace the logs Close all...

Page 20: ...ach burner to the burner pan slide to the right lift up and out For the air shutter settings see the chart below Closing the air shutter will cause a more yellow flame but can lead to carboning Openin...

Page 21: ...S IDENTIFIES ITEMS WHICH ARE NOT ILLUSTRATED FOR FURTHER INFORMATION CONTACT YOUR NAPOLEON DEALER TERMINAL KITS ROOF TERMINAL KITS COMPONENTS COMMON TO BOTH UNITS PART DESCRIPTION 1 W725 0042 SIT VALV...

Page 22: ...A U TI ON H OT 45 21 19 20 18 17 46 50 49 47 52 52 52 44 65 5 4 13 35 29 27 24 26 28 31 16 40 11 1 2 3 22 57 55 54 58 56 WARNING This is a fast acting thermocouple It is an integral safety component R...

Page 23: ...d valve connection replace thermocouple replace valve replace replace Main burner goes out pilot stays on Pilot flame is not large enough or not engulfing the thermopile Thermopile shorting Remote wal...

Page 24: ...ocked ensure air shutter opening is free of lint or other obstruc tions Blower does not turn on Turn blower switch on turn turbo rear burner off and front burner to low When blower turns on re adjust...

Reviews: