GSM-4/GSM-5
SATEL
46
DloadX key [Key]
– the string of 12 alphanumeric characters (digits, letters and special
characters) defining the key with which the data sent to the
D
LOAD
X program will be
encrypted. The module will only establish connection to the program using the correct key.
encrypted transmission [Encryption]
– if this option is enabled, the data transmission
between module and program will be encrypted. The option must be enabled.
Communication Integra-GuardX [GuardX download]
Server address
– the address of computer with the G
UARD
X program, with which the module
(connected to the INTEGRA control panel through RS-232 port) is to communicate using
the GPRS technology. It can be entered as an IP address or as a name.
Server from SMS [Any address]
– if this option is enabled, the address of server, to which
the module is to connect, and the port number can be entered in the content of SMS
message initiating the connection. If the address is not entered, the module will connect to
the computer whose address has been programmed in the module.
Port [Server port]
– the number of port on which the communication with the G
UARD
X
program will take place.
Initiating SMS [SMS prog.
GuardX]
– the control command that must be included in the
SMS message sent to the telephone number of GSM module connected to the control
panel, so that the module can establish communication with the G
UARD
X program using
the GPRS technology.
GuardX key [Key]
– the string of 12 alphanumeric characters (digits, letters and special
characters) defining the key with which the data sent to the
G
UARD
X program will be
encrypted. The module will only establish connection to the program using the correct key.
6.2.13 "Firmware update" tab
Remote update of the module firmware by means of GPRS is possible for modules with the
u-blox LEON-G100 industrial GSM telephone.
For information on the firmware update server please visit the www.satel.eu site.
Fig. 24. "Firmware update" tab (GSM-5 module).
Update server [Server address]
– the address of server to which the module is to connect
for firmware update. It can be entered as an IP address or as a name.
Port [Server port]
– the number of server port shown in the form of decimal numbers.
SMS initiating update [SMS firmware]
– the control command that must be included in the
SMS message sent to the telephone number of GSM module so as to initiate the firmware
update.
Server from SMS [Any address]
– if this option is enabled, the address of server, to which
the module is to connect, and the port number can be entered in the content of SMS
message initiating the connection. If the address is not entered, the module will connect to
the server whose address has been programmed in the module.