NETWORK CONTROL
2
English
163
z
When the maximum number of PCs (15) is connected to
the digital video recorder and then an upper-level user
accesses the unit from a different PC, the most recent
lower-level user is automatically disconnected and priority
is given to the upper-level user.
An error message is displayed on the PC of the
disconnected user. (
J
P.164)
z
If entry of an incorrect password is repeated or [Cancel] is
clicked, [AUTHENTICATION ERROR] displayed.
z
If a user clicks a restricted button during computer control,
the password input screen is displayed to verify the
required user level.
4
Select a language and click [OK].
The operation screen is displayed and computer control is
now enabled.
z
A connection may not be possible via a proxy server. In
this case, cancel the proxy settings.
z
Due to certain PC performance levels and specifications, a
portion of the video may not be displayed. In this case, go
to [Tools]
J
[Internet Options]
J
[Temporary Internet Files]
J
[Settings] in Internet Explorer, and then reduce [Amount
of disk space to use].
1
Click the button on the operation
screen of the PC.
The connection is cancelled and control rights are returned to
the unit.
z
To forcibly cancel PC access from the unit, press and hold
the [SHUTTLE HOLD] button for at least 3 seconds.
z
Access from the PC is not permitted for a period of 10
seconds after access is cancelled.
z
The access connection is also cancelled and control rights
then switch back to the unit whenever communication with
the PC is not possible for a period of about 1 minute or
more.
z
If the browser is closed without clicking the
button,
approximately 1 minute is required before reconnection is
possible.
Messages related to the switching of control or the network
connection status may be displayed on-screen at any time.
When control rights are switched to the PC
“NETWORK CONTROL” is displayed on the monitor.
The “NETWORK CONTROL” message is displayed when
connected to a network, regardless of whether control is
performed from the PC or the digital video recorder
z
The “NETWORK CONTROL” message is not displayed
when the network control setting (
J
P.128) connection
display is set to “OFF” using the unit’s setting menu.
Disconnecting
Messages displayed when connected
Display on the unit
02
01-01-07 00:00:00 REC REPEAT EN A ALARM 0000000
NETWORK CONTROL
NETWORK CONTROL
NETWORK CONTROL