CHAPTER 2. MMC Programming
2-168
© SAMSUNG Electronics Co., Ltd.
(Continued)
Timer Name
Default
Range Unit
Description
CAMP ON RECALL
30
0-250 SEC
This timer controls the time a camped-on call
will stay at a destination before recalling to the
transferring station.
CID MSG RECEIVE
6
1-25 SEC
The amount of time that the system will allow
a valid message from the analogue CID trunk.
CID DSP ALLOC TM
500
000-500
MSEC
Caller ID (CLI) Digital Signal Processor
Allocation timer - the length of time the DSP is
in-circuit to decode analogue Caller ID.
(This option may not be available in certain
OfficeServ models.)
CLI DISPLAY TIME
5
1-25 SEC
The amount of time that the Caller ID
information remains on the phone’s display.
CO CLEAR TIME
30
0-250 SEC
The length of time a Direct Trunk Select key
remains busy after cleardown.
CO CONFIRM TIME
3
0-250
MIN
According to MMC 314 CO CONFIRM type,
the outgoing call will be disconnected after
this timer expires or the outgoing caller will
hear the confirm tone.
CO-CO DISCONNECT
20
1-250 MIN
This timer monitors the duration of an
unsupervised conference; when it expires,
both trunks are disconnected.
CONFIRM TONE TM
1000
100-2500
MSEC
The tone heard when a feature is activated or
deactivated.
CRD TONE INT TM
30
0-250 SEC
This is the call record tone interval time. An entry
other than zero will cause a tone to be heard by
all the parties in a recorded conversation.
The range for the tone is 001 (every second) to
255 (every 255 seconds). A value of 000 means
no tone. Requires an SVMi card.
DIAL PASS TIME
3
0-25 SEC
This timer monitors the time before
connecting the transmit of the phone to the
trunk side of an outgoing call.
DISA DISCONNECT
30
1-250 MIN
This timer controls the maximum duration of a
DISA call.
DISA LOCK OUT TM
30
1-250 MIN
This timer controls how long a DISA call is not
allowed to be made after the DISA error
counter has expired (MMC 500).
DISA NOANS DISC.
30
0-250 SEC
This timer determines when a DISA call is
disconnected by force when a called party
does not answer.
DISA PASS CHECK
30
1-250 MIN
This timer defines the period before the
system clears the incorrect passcode counter.
Summary of Contents for OfficeServ 7000 Series
Page 1: ...GABD 000264 Ed 02 OfficeServ 7000 Series Call Server Programming Manual ...
Page 6: ...Revision History IV SAMSUNG Electronics Co Ltd This page is intentionally left blank ...
Page 18: ...TABLE OF CONTENTS XVI SAMSUNG Electronics Co Ltd This page is intentionally left blank ...
Page 82: ...CHAPTER 2 MMC Programming 2 44 SAMSUNG Electronics Co Ltd RELATED ITEMS NONE ...
Page 486: ...ABBREVIATION VI SAMSUNG Electronics Co Ltd This page is intentionally left blank ...