[209] ASSIGN ADD-ON MODULE
Designates to which phone an Add-On Module (AOM) is assigned. There is no limit to the
number of AOMs that can be assigned in the system. A maximum of four AOMs can be
assigned to a keyset.
CONDITIONS
An AOM cannot be designated as Master. If no AOM exists in the system, the ‘AOM NOT
EXIST’ message is displayed.
DEFAULT DATA
MASTER: NONE
ACTION
DISPLAY
1) Press Transfer button and enter 209.
Display shows first AOM:
[301] AOM MASTER
MASTER:NONE
2) Dial AOM number.
OR
[301] AOM MASTER
MASTER:NONE
Use Volume button to scroll through AOM numbers and
use Soft buttons to move cursor.
3) Enter station number. (e.g., 301)
OR
[301] AOM MASTER
MASTER:201
Use Volume button for selection of stations and press
Right Soft button to return to step 2.
4) Press Transfer button to save and exit.
OR
Press Speaker button to save and advance to next
MMC.
RELATED ITEMS
NONE