CHAPTER 2. MMC Programming
2-414
© SAMSUNG Electronics Co., Ltd.
(Continued)
No
Code
Alarm Name
Definition
08
MJA08
FAN Out of Order
A FAN does not work.
09
MJA09
FAN Recovery
A FAN which did not work starts to operate correctly
before system stops.
10
MJA10
CPU Overload
CPU Overload
11
MJA11
CPU Overload
Rec
CPU Overload Recovery
12
MJA12
FLASH FORMAT
Err
FLASH FORMAT Error
13
MJA13
Invalid MMC Halt
An Invalid MMC card has inserted in SYSTEM.
So system is halted.
14
MJA14
DUAL PWR Error
Dual Power Error alarm
15
MJA15
DUAL PWR
Recovry
Dual Power recovery alarm
16
MJA16
D-PWR FAN
Error
Dual Power FAN Error alarm
17
MJA17
D-PWR FAN
Recov
Dual Power FAN recovery alarm
18
MJA18
PoE PWR Error
PoE Power Error alarm
19
MJA19
PoE PWR
Recovry
PoE Power recovery alarm
20
MJA20
PoE FAN Error
PoE Power FAN Error alarm
21
MJA21
PoE FAN
Recovry
PoE Power FAN recovery alarm
22
MJA22
PoE Battry Error
PoE Power Battery Error alarm
23
MJA23
PoE Battry Recov PoE Power Battery recovery alarm
24
MJA24
MAIN PWR Error
PoE Power Battery Error alarm
25
MJA25
MAIN PWR
Recovry
PoE Power Battery recovery alarm
25
MJA26
MEDIA NOT
UMOUNT
Media Card Out without dismounted
-
MJA27
SYS Overheat
System Overheat alarm
-
MJA28
SYS High Temp
System High Temperature alarm
-
MJA29
SYS Normal
Temp
System Normal Temperature alarm
-
MJA30
PCM SW Init Fail
PCM Switch initial fail alarm
-
MJA31
PCM SW Init Rec
PCM Switch initial recovered alarm
-
MJB--
LCP/TASK Error
LCP or TASK Fault
Summary of Contents for OfficeServ 7000 Series
Page 1: ...GABD 000264 Ed 02 OfficeServ 7000 Series Call Server Programming Manual ...
Page 6: ...Revision History IV SAMSUNG Electronics Co Ltd This page is intentionally left blank ...
Page 18: ...TABLE OF CONTENTS XVI SAMSUNG Electronics Co Ltd This page is intentionally left blank ...
Page 82: ...CHAPTER 2 MMC Programming 2 44 SAMSUNG Electronics Co Ltd RELATED ITEMS NONE ...
Page 486: ...ABBREVIATION VI SAMSUNG Electronics Co Ltd This page is intentionally left blank ...