[863] SYSTEM NODE INFORMATION
This MMC is the program that specifies the system information of SPNET (Samsung
Protocol Networking). It is useful when many systems are consisted through SPNET and
interlocked with LCR. There are maximum 2000 entries.
No
Option
Description
0
ACCESS NUM
Other System’s ID
1
IP ADDR
Other System’s IP address
2
TEL NUMBER
Rerouting Trunk Number (excluding VoIP Trunk Number).
If SPNET function is not work, Call is rerouted through this trunk
3
MAX COUNT
If you dial a valid digit string until Max Count number, the system
set up call.
4
NO MGI
No: Use MGI as of old, Yes: Don’t use MGI
(This option can be shown in case that MMC 861 ‘MPS
SERVICE’ set to ENABLE)
SPNET is VoIP Network function developed by Samsung. (it is not standard
function.)
CONDITIONS
LINK ID should not be inputted at MMC 820 SYSTEM LINK and ACCESS NUMBER &
TEL NUMBER should be inputted at LCR table.
ACTION
DISPLAY
1) Press Transfer button and enter 863.
Display shows:
(0001) ACCESS NUM
2) Enter the node entry number.
OR
(0001) ACCESS NUM
Press Volume button to select and press Right Soft
button to move cursor.
3) Enter the option number
OR
(0001) ACCESS NUM
Press Volume button to select and press Right Soft
button to store.
4) Enter the access number.
(0001) ACCESS NUM
1
Summary of Contents for OfficeServ 7000 Series
Page 1: ...GABD 000264 Ed 02 OfficeServ 7000 Series Call Server Programming Manual ...
Page 6: ...Revision History IV SAMSUNG Electronics Co Ltd This page is intentionally left blank ...
Page 18: ...TABLE OF CONTENTS XVI SAMSUNG Electronics Co Ltd This page is intentionally left blank ...
Page 82: ...CHAPTER 2 MMC Programming 2 44 SAMSUNG Electronics Co Ltd RELATED ITEMS NONE ...
Page 486: ...ABBREVIATION VI SAMSUNG Electronics Co Ltd This page is intentionally left blank ...