background image

 
 
 

 
 

Doc.-ID: 150903-PT08BA-TG-ExCam IPM1145-(L)_en_rev.02.docx, page 9 of 40 

 

At a cable connection length of 

 3 m

 

(without integrated pressure barrier

/ with  

 

elastomer sealing on the outer sheath) e.g.:    
„ADE 4F MsNi Type5 - M20x1.5 (

CAPRI

)“,  

with additional strain relief; 
At a connection cable length of 

< 3m

:  

(

with integrated pressure barrier

 / epoxide 

compound grouting of the single conductors 
and duroplast/elastomer sealing of the outer 
sheath) e.g.: 

„8163/2 PXSS2K - M20x1.5 (

R. 

Stahl GmbH

)“ 

Outer diameter: 

9.0 ± 0.2mm  

Wall thickness: 

0.9 ± 0.1mm 

Bending radius: 

10 x outer diameter at installation 

 

5 x outer diameter after installation 

Tensile: 

Max. 140N 

Temperature range: 

-10° C to +50° C (at point of installation) 

 

-60° C to +80° C (fixed installed) 

Conductor design: 

4 x 2 x AWG22/1 blank, CAT.6a 

Isolation: 

SFS-PE foamed 

Core diameter: 

1.52 ± 0.02 mm 

Color code: 

IEC 708-1 

Pair shielding: 

Compound aluminum foil 

Shielding: 

Copper braid, multiple wires 0-10 vz, opt. cov-
erage approx. 85% 

Outer sheath: 

PUR FHF 

Characteristics: 

PUR halogen free, flame resistant (EN 60332-
1-2), UV and ozone resistant, high chemical re-
sistance, EMV shielded  

 

(q.v. www.samcon.eu, data sheet SKD02-T) 

 
User interface: 

P

(Plug) version: RJ-45 Stecker (EIA/TIA- 

568B), e.g. Weidmüller IE-PS-RJ45-FH-BK, 
Phoenix  Contact VS-08-RJ45-5-Q/IP20 etc., 

 

10BASE-T/100BASE-TX PoE 

K

(terminal block) version: about 12 cm stripped: 

8 x single conductors twisted pair (solid conduc-
tor  A=0.33mm

2

, ø=0.64 mm approx. 6 mm 

stripped), 1 x shield (Cu braid tinned 1.5 mm

2

ferule color code according to DIN 46228) 

 

10BASE-T/ 100BASE-TX PoE 

 
 

Summary of Contents for ExCam IPM1145

Page 1: ...ExCam IPM1145 L User manual...

Page 2: ...L PoE 13 2 8 2 ExCam IPM1145 13 2 8 3 ExCam IPM1145 L 13 2 9 Other technical data 13 3 Safety guidelines 16 4 Illustration of the model key 17 5 Commissioning 19 5 1 Step 1 Installation 19 5 2 Step 2...

Page 3: ...XX X L L 22 Table 5 2 Pin assignment SKD02 T and plug contact RJ45 23 Figure 5 6 RJ45 Contact assignment 23 Figure 5 7 SKD02 T Pin assignment 24 Table 5 3 Pin assignment supply cable for heating type...

Page 4: ...08BA TG ExCam IPM1145 L _en_rev 02 Author Thiemo Gruber Date September 03 2015 Last revision November 06th 2018 Rev Index Date Name Remarks Authorization of the EX Supervisor 0 Sep 03 2015 T Gruber Co...

Page 5: ...t difficult light settings day night functionality edge storage individually configurable H 264 and Motion JPEG video streams an intelligent and fast P Iris aperture control as well as optional I O in...

Page 6: ...ion level IP 68 IEC EN 60529 Transportation and storage ambient temperature EX 1 ExCam IPM1145 60 C to 65 C temperature class T6 60 C to 70 C temperature class T5 ExCam IPM1145 L 60 C to 60 C temperat...

Page 7: ...60079 31 2010 Others IEC 60079 14 2013 EN 60079 14 2014 DIN 7080 2005 05 IEC 60529 1989 A1 1999 DIN EN 60529 1991 A1 2000 DIN VDE 0118 1 2010 02 2 2 Electrical parameters of the camera module 2 2 1 Ex...

Page 8: ...ous power rating at the artic temperature range TAMB 60 C is P 60 C 26 8 W at a saturated condition The typical start up peak at the low temperature range 1x HP05 heating element is Imax 4000mA The ty...

Page 9: ...point of installation 60 C to 80 C fixed installed Conductor design 4 x 2 x AWG22 1 blank CAT 6a Isolation SFS PE foamed Core diameter 1 52 0 02 mm Color code IEC 708 1 Pair shielding Compound alumin...

Page 10: ...s 12 5 x outer diameter occasional movement 4 0 x outer diameter fixed installation Conductor design 3G1 5 0012838 3 x 1 5 mm2 1 4 mm Fine wired tinned copper strand according to IEC 60228 VDE 0295 cl...

Page 11: ...to DIN 46228 Sheath about 12 cm stripped and furnished with bend relief shrink tubing 2 6 Technical specification of the camera modules Note Technical details of the internal CCTV module such as light...

Page 12: ...table intensity and illumination angle typical range up to 15 m Light sensor for automatic activation or deac tivation of the infrared diodes Includes a particularly developed chloroprene rubber adapt...

Page 13: ...IN EN 10027 2 2015 07 making system for steel Housing material standard MNo 1 4404 X2CrNiMo17 12 2 AISI 316L V4A 7 Functional temperature range concerning the operational temperature range of the inst...

Page 14: ...Aluminum die cast zinced protection housing of the camera module polyamide PA6 6 PA2000 and polyoxymethylen POM isolators and supporting adapters T08 aluminum univer sal adapter EN AW ALSi1MgMn PTC c...

Page 15: ...m K1 flange 113 0mm x 138 5mm x 226 0mm K2 flange 113 0mm x 138 5mm x 260 2mm PoE Fitting of the flame proof gap preventing the transmission of ignition cylinder EX of the T07 VA2 1 x x housing Flange...

Page 16: ...inish of the Ex d housing Gy lon flat sealing etc The resistance significantly depends on the following factors Temperature concentration duration and media type liquid gas steam etc The resistance to...

Page 17: ...rding the installed camera module and characteristics Sensor resolution light sensi tivity camera angle of view aperture control power intake zoom charac teristics wide tele range optical digital moto...

Page 18: ...ank 0 33 mm2 0 64 mm approx 6 mm striped 1x shield CU braid tinned 1 5 mm2 with ferules blue lflex 440P Supply 3G1 5mm2 Cu Sheath about 12 cm stripped and furnished with bend relief shrink tubing P Pl...

Page 19: ...red location Mounting options and conditions accessories as well as safety guidelines are described in the EX installation manual of the T08 ExCam series 5 2 Step 2 Electrical connection Attention The...

Page 20: ...the user is prohibited Depending on the model option the ending of the camera s cable con nection is either stripped to the blank Cu conductors or furnished with a plug 5 2 1 Potential equalization Fi...

Page 21: ...and supply cable Figure 5 3 ExCam IPM1145 L T08 VA2 1 K1 BOR C XXX K X Cable gland 2 optional lflex 440P Power supply for CB06 circuit board PTC heating elements and further devices if applicable via...

Page 22: ...gure 5 4 ExCam IPM1145 L T08 VA2 1 K1 BOR C XXX P X Figure 5 5 ExCam IPM1145 L T08 VA2 1 K1 BOR C XXX X L L ExCam IPM1145 L Use PoE PSE for 802 3at type 1 class 3 or Use PoE PSE for 802 3at type 2 cla...

Page 23: ...E 48 VDC BU 4 0 64 mm2 Solid conductor n a PoE 48 VDC WH BU 5 0 64 mm2 Solid conductor Rx PoE GND Rx GN 6 0 64 mm2 Solid conductor n a PoE GND WH BN 7 0 64 mm2 Solid conductor n a PoE GND BN 8 0 64 mm...

Page 24: ...ignment supply cable for heating type L Power supply fuse type H q v table 5 4 or upon request available Note If the camera is equipped with a pneumatic camera cooling system SAMCON cool Jacket for mo...

Page 25: ...t the proper functioning of the operating device in accordance with this user man ual and all other applicable regulation has been executed Attention Incorrect installation and operation of the camera...

Page 26: ...es at the lens of the ExCam IPM1145 L are exclusively done via the Web Interface or the visualization software Mechanical adjustments at the varifo cal lens by the user are not possible The camera mod...

Page 27: ...e 3 0 10 5 mm Horizontal angle of view 95 wide 34 tele Iris control Precision automatic MOD Minimum object distance 0 30 m wide 1 00 m tele Table 5 6 Lens data Information If not determined differentl...

Page 28: ...Make sure you have a secure foothold Avoid static charge 5 4 2 Opening the pressure resistant housing Opening the pressure resistant housing DIN EN 60079 1 2008 of the ExCam IPM1145 L is only allowed...

Page 29: ...rotection roof 2 2 To open the stainless steel enclosure T07 VA2 1 x x of the ExCam IPM1145 L loosen the eight hexagon socket screws DIN 912 ISO 4762 located at the cable gland flange of the stainless...

Page 30: ...re controller the camera module and the optical module are fixed to the cable gland flange Beware also of tilting and work very carefully to avoid damaging the components Avoid skin and clothing conta...

Page 31: ...IPM1145 L installation components Axis M1145 L IP camera Temperature controlCB06 PTC heating element DBK HP05 Auxiliary relays for magnet valve control for type H IR Anti reflexion adapter flexible c...

Page 32: ...ed or deleted via the web interface they are also available in a download list or as an ftp file to the network The videos saved on the storage card can be accessed also via the FTP server within the...

Page 33: ...the control button pressed until the status light 6 Abb 6 14 blinks yellow This may take up to 30 seconds 4 Release the control button As soon as the status light is green the camera mod ule Axis M114...

Page 34: ...ufficiently please clean it with a clean cloth and suitable cleaning deter gent Afterwards re lubricate it with a suitable lubrication agent e g Molykote P 40 paste for standard applications or specia...

Page 35: ...acintosh and Firefox with Windows and additional operating systems To carry out video streaming via the Microsoft Internet Explorer installing the AXIS Media Control AMC is required The installation r...

Page 36: ...not possible to assign the IP address it might be necessary to change the firewall settings or t consult the network administrator The AXIS IP Utility tool automatically recognizes all ExCam devices a...

Page 37: ...etermining the password please fol low the below steps 1 Click on the button Create self signed certificate 2 Enter the desired information and click OK The certificate is issued and the password can...

Page 38: ...e necessary they have to be initiated and or executed 8 Repairs and Maintenance Repairs must only be carried out with original parts of SAMCON Prozessleittechnik GmbH Damaged pressure resistant housin...

Page 39: ...Doc ID 150903 PT08BA TG ExCam IPM1145 L _en_rev 02 docx page 39 of 40 11 Notes...

Page 40: ...Doc ID 150903 PT08BA TG ExCam IPM1145 L _en_rev 02 docx page 40 of 40 Schillerstra e 17 35102 Lohra Altenvers www samcon eu info samcon eu fon 49 6426 9231 0 fax 31...

Reviews: