Doc.-ID: 150903-PT08BA-TG-ExCam IPM1145-(L)_en_rev.02.docx, page 7 of 40
Product compliance
Gas explosion protection:
- IEC 60079-0:2011, EN 60079-0:2012
- IEC 60079-1:2007, EN 60079-1:2008
- IEC 60079-11:2011, EN 60079-11:2012
- IEC 60079-18:2009, EN 60079-18:2009
- IEC 60079-28:2006/ ISH1:2014,
EN 60079-28:2007 (Beiblatt 1:2014-09)
- GOST R IEC 60079-0:2011
- GOST IEC 60079-1:2011
Dust explosion protection:
- IEC 60079-31:2008, EN 60079-31:2009
- GOST R IEC 60079-31:2010
Others:
- IEC 60079-14:2013, EN 60079-14:2014
- DIN 7080:2005-05
- IEC 60529:1989 + A1:1999,
DIN EN 60529:1991 + A1:2000
- DIN VDE 0118-1:2010-02
2.2
Electrical parameters of the camera module
2.2.1
ExCam IPM1145-(L) (PoE+) (Camera and Heater)
Power supply:
PoE, IEEE 802.3at type 2 class 4
Reference power:
48 V DC (44...54 V DC)
Maximum power input:
24.9 W (30 W from the PSD)
2.2.2
ExCam IPM1145
Power supply:
PoE, IEEE 802.3af/ 802.3at type 1 class 2
Reference power:
48 V DC (44...54 V DC)
Maximum power input:
6.0 W
2.2.3
ExCam IPM1145-L
Power supply:
PoE, IEEE 802.3af/ 802.3at type 1 class 3
Reference power:
48 V DC (44...54 V DC)
Maximum power input:
10.5 W