Doc.-ID: 150903-PT08BA-TG-ExCam IPM1145-(L)_en_rev.02.docx, page 33 of 40
Please pay attention when inserting / extracting the storage card. Do not damage elec-
tronic parts, clamps, the CB06 circuit board, or the cable gland! Do not bend the mount-
ing adapter as otherwise the optical axis of the equipment is not guaranteed anymore!
Bei der ExCam IPM1145-(L) den schwarzen Infrarot-Antireflexionsadapter aus Neopren
(siehe Abb.6.13) keiner mechanischen Belastung aussetzen oder diesen entfernen.
When touching electrical components, potential equalization (grounding
of the body) has to be observed (ESD clothing, PE wristband etc.)!
5.4.4
Hardware Reset
In order to change all parameters, including the IP address, of the ExCam IPM1145-(L),
to the default settings, a hardware reset has to be carried out.
It is possible to reset the parameters either via the web interface or manually. If the cam-
era cannot be accessed anymore via the network or in an uncontrollable state, the reset
has to be done manually. To do so, please follow the steps below:
1. Disconnect the camera module (Axis M1145-(L)) from power
2. Press control button 8 (q.v. figure 5.14); simultaneously switch-on power (PoE)
3. Keep the control button pressed until the status light 6 (Abb.6.14) blinks yellow.
This may take up to 30 seconds
4. Release the control button. As soon as the status light is green, the camera mod-
ule Axis M1145-(L) has been reset to Axis default settings. This may take up to
one minute. If no DHCP Server is available within the network, the IP address is
192.168.0.90 (subnet masking 255.255.255.0).
5. Now, IP address and password can be re-assigned. If the hardware reset was not
successful or if the cameras still does not work properly anymore, (faulty browser
visualization, picture freezing, control functions are not carried out, the system
generally displays slow response times etc.), please re-install the applicable firm-
ware or carry out an update (qv. chapter 6.4).
5.4.5
Closing of the pressure-resistant housing
For closing the housing, please follow, in reversed order, the steps described in the chap-
ter 6.4.2 regarding the opening of the housing. Do not use any other screws than those
which are part of the delivery scope. For the execution with a „K1“ cable gland, 8 x cylin-
der head screws M4 x 0.7 (ISO metric right-hand thread) with a thread length of 12 mm
(DIN 912/ ISO 4762, quality 6g) are used. The material of the screw connection is varia-
ble, e.g. stainless steel MNo. 1.4301 (A2-70) corresponding to the pressure resistant
housing or a titan execution (Ti22) in metallic red.