Doc.-ID: 150903-PT08BA-TG-ExCam IPM1145-(L)_en_rev.02.docx, page 25 of 40
Potential/
Pin no.
Color Ölflex®
440P
(IEC60757)
Cond.
design
Voltage
U
N
Nominal
power I
N
Nominal
capacity P
N
Power supply
fuse rating
L+ / 1
BK
1.5mm
2
,
litz wire
+24 VDC
486 mA
11.7 W
Fine fuse
1000 mA -f- flink
L- / 2
BK
1.5mm
2
,
litz wire
0 VDC / GND
PE / 3
GN/GY
1.5mm
2
,
litz wire
0 VDC
Table 5.4
– Pin assigment supply cable for cooling type H
5.2.3
Tests prior to switching on voltage
Attention!
Prior to commissioning, all tests as indicated by the national regula-
tions have to be executed. In addition, it is mandatory that the proper
functioning of the operating device in accordance with this user man-
ual and all other applicable regulation has been executed
Attention!
Incorrect installation and operation of the camera may lead to a loss of
warranty!
Attention!
When commissioning the camera at temperature below 0 °C, it has to
be secured that the camera is not switched-on prior to the housing
heating. The PTC heating has to warm up the housing before turning
on the camera. This can be realized, for example, by the means of an
external time relay.
5.3
Testing of the status LED
The
camera module’s status LED is located in the back of the stainless steel enclosure
and is only visible when the housing is open.
The status of the ExCam IPM1145-(L) is reflected by the LED indicators is as follows: