Doc.-ID: 150903-PT08BA-TG-ExCam IPM1145-(L)_en_rev.02.docx, page 29 of 40
If the T08 ExCam IPM1145-L is equipped with a protection roof, this has to be removed
first. To do so, loosen the 4 x 8mm screws M4*0.7 situated on the both ends of the
brackets (figure 5.10 and 5.11).
Figure 5.10
– Removing the protection roof (1/2)
Figure 5.11
– Removing the protection roof (2/2)
To open the stainless steel enclosure (T07 VA2.1.x.x) of the ExCam IPM1145-(L), loosen
the eight hexagon socket screws (DIN 912/ ISO 4762) located at the cable gland flange
of the stainless steel housing, including the washer springs (DIN 127 A) (q.v. figure 5.12).
Avoid skin or clothing contact with the screw threads as they dispose of LOCTITE ®
243™ (chemical basis: Dimethacrylatester). It is used to protect the screws from losing
due to shocks, vibrations but also for sealing purposes. It is not allowed to open the sight
glass flange!