Doc.-ID: 150903-PT08BA-TG-ExCam IPM1145-(L)_en_rev.02.docx, page 10 of 40
2.5
Power Supply cable (optional)
Description:
Ölflex® 440P
4
(
U.I. Lapp GmbH
), power supply
for the PTC heat load circuit as well as for the
electronical regulation of the CB06 for T08 Ex-
Cam with the model key
„L“ and „LL“,
(DIN EN 60079-14: 2014 conform)
Sheath color:
Silver grey (GY) matt, similar RAL7001
Ex d marshalling:
via cable gland 2
5
located on the left (according
to DIN EN 60079-14:2014
[Chapter
10.6.2])
At a cable connection length of
≥
3 m
:
(without integrated pressure barrier
/ with
elastomer sealing on the outer sheath) e.g.:
„ADE 4F MsNi Type5 - M20x1.5 (
CAPRI
)“,
with additional strain relief;
At a connection cable length of
< 3m
:
(
with integrated pressure barrier
/ epoxide
compound grouting of the single conductors
and duroplast/elastomer sealing of the outer
sheath) e.g.:
„8163/2 PXSS2K - M20x1.5 (
R. Stahl GmbH
)“
Outer diameter:
7.5 mm
Outer sheath:
Polyurethane mixture TMPU according to EN
50363-10-2 / VDE 0207-363-10-2
Bending radius:
12.5 x outer diameter (occasional movement)
4.0 x outer diameter (fixed installation)
Conductor design:
3G1.5 (0012838), 3 x 1.5 mm
2
(ø=1.4 mm),
Fine wired tinned copper strand according to.
IEC 60228 / VDE 0295, class 5, with protective
earth (GN/YE)
Copper index:
43.0 kg/km
Weight:
96.0 kg/km
Tensile strength:
15 N/mm
2
Characteristics:
Resistant to oil and drilling fluids according to
IEC 61892-4: supplement D, wear and notching
resistant, halogen free (VDE 0472-815) and
flame-retardant according to IEC 60332-1-2, re-
sistant to hydrolysis and microbes, UV re-
sistant, additional testing requirements accord-
ing to IEC 60811, EN 50396 and EN 50396
4
Further cables available upon request, e.g. „Ölflex® Petro FD 865 CP“ (high resistance against oil and drilling liquids) or „XPLE
Armoured 3 x 2.5
“ (extremely robust, particularly designed for offshore environments)
5
According to the current standard DIN EN 60079-14:2014, the dimensioning/execution of the cable gland with or without integrated
pressure barrier / compound grouting does not depend anymore on the marked gas explosion group (IIB, IIC) or the Ex d pressure
chamber volume (<2000cm
3
, ≥2000cm
3
) but solely on the length of the suitable connection cable
(<3m, ≥3m)