Doc.-ID: 150903-PT08BA-TG-ExCam IPM1145-(L)_en_rev.02.docx, page 6 of 40
2
Technical Data
2.1
Parameters of the explosion protection
Identification marks according to
Directive
94/9/EG
(until April 20, 2016)
:
Directive 2014/34/EU:
II 2G (zone 1 and 2)
II 2D (zone 21 and 22)
I M2
Explosion protection (gas):
Ex d IIC T6 Gb or
Ex d IIC T5 Gb or
Ex d IIB T6 Gb or
Ex d IIB T5 Gb
Explosion protection (dust):
Ex tb IIIC T80°C Db IP68 or
Ex tb IIIC T95°C Db IP68 or
Ex tb IIIB T80°C Db IP68 or
Ex tb IIIB T95°C Db IP68
Explosion protection (mining)
Ex d I Mb
Protection level:
IP 68 (IEC /EN 60529)
Transportation and storage
ambient temperature (EX)
1
ExCam IPM1145:
-60°C to +65°C
(temperature class T6)
-60°C to +70°C
(temperature class T5)
ExCam IPM1145-L:
-60°C to +60°C
(temperature class T6)
-60°C to +65°C
(temperature class T5)
Nominated body:
TÜV Rheinland (number 0035)
EC Type Examination:
TÜV 14 ATEX 7539 X_1st supplement
IECEx TUR 14.0026X_issue No.1
Additional certificates:
EAC-Ex TC_RU_C_DE.MIO62.B.01921
Test protocol ATEX:
557/Ex.539.01/14
Test report IECEx:
DE/TUR/ExTR14.0026/01
Quality Assessment Report:
DE/BVS/QAR14.0006/00
1
Maximum ambient temperature range relevant for explosion protection might deviate to the maximum functional temperature range.
For maximum functional temperature range (MTBF) see chapter 3.12