Doc.-ID: 150903-PT08BA-TG-ExCam IPM1145-(L)_en_rev.02.docx, page 24 of 40
Figure 5.7
– SKD02-T Pin assignment
If the camera is equipped with a heating or a cooling (type L, LL, LH), a second power
supply with a separate supply protection at the „L+“ has to be available. Standardly, the
supply is carried out via the supply cable Ölflex® 440P (cable gland 2, q.v. figure 5.2 and
5.5). Connection assignment and supply protection according to table 5.3.
Potential/
Pin no.
Color „Ölflex
Robust 440P“
(IEC60757)
Cond.
design
Voltage
Maximum power in-
put / protection
(type L)
Maximum power in-
put / protection
(type LL)
L+ / 1
BK
1.5 mm
2
litz wire
+24 VDC
20 W / fuse (L+) 2000
mA -T- time lag
(high inrush current!)
40 W / fuse (L+) 4000
mA -T- time lag
(high inrush current!)
L- / 2
BK
1.5 mm
2
litz wire
0 VDC / GND
Table 5.3
– Pin assignment supply cable for heating type L
Power supply fuse type H q.v. table 5.4 or upon request available!
Note:
If the camera is equipped with a pneumatic camera cooling system (SAMCON
cool.Jacket
for model key type H), also an additional cable gland at the camera housing
is required. A
„decentral“ magnet valve (ex or non-ex, depending on the application) is
accessed in order to control the supply of the pressurized air (cold air feed). For further
information, please refer to the applicable user manual of this accessory. The magnet
valve’s power supply is executed via an integrated circuit board control and the transistor
outputs of the Axis M1145-(L) camera module. The electrical control of the cool.Jacket
can either be done via the SKD02-T cable (4 x free conductors at PoE supply Mode A/
phantom power) or a 3G1.5 supply cable of type Ölflex® 440P.
The standard wiring is executed via the power cable and as described in table 6.4 below:
4
2
6
3
9 (shield/
GND)
5
8
7
1
10 (shield)