Chapter 5: Troubleshooting
226
Status signalling
01020 to
01029
Too low
temperature
warning
Low ambient
temperature is
causing the
performance of the
terminal to be
degraded or halted.
The terminal will
assume radio
silence if the
problem is in the
ACM module of the
antenna.
Move the terminal
to a warmer
location.
For information on
ambient
temperature limits,
see the installation
manual.
01110 to
01119
Temperature
too high
(critical)
Terminal:
Critically
high temperature is
causing the
terminal to shut
down.
Antenna:
Critically
high temperature is
causing the
antenna to stop
transmission.
If possible, move
the failing unit to a
cooler location.
For information on
ambient
temperature limits,
see the installation
manual.
Contact your
distributor if the
problem persists.
ID
Event Text
Explanation
Remedy