System Description, Setup, and Quick Start
RTR-4 Operator’s Manual
3-18
SAIC Proprietary
120300 Rev. D
Quick Start
System Initialization
Description
Use this procedure to prepare the RTR-4 for X-raying an object.
Prerequisites
Verify the following prerequisites are completed before beginning
this procedure:
• The appropriate setup procedure has been completed.
• The source and imager are correctly positioned by the object to
be X-rayed and the source, imager, and controller have been
turned on.
Procedure RTR0003
Initialize the RTR-4 as follows:
Acquiring an X-Ray Image
Description
Follow this procedure to X-ray an object.
Prerequisites
Verify the following prerequisites are completed before beginning
this procedure:
• The RTR-4 is fully configured in accordance with the
applicable setup procedure.
• The Source and Imager units are correctly positioned around
the item to be X-rayed and the source Safety Keyswitch has
been turned 90° clockwise.
• The RTR-4 imaging software has been properly initiated and
is running.
STEP
ACTION
1
At the controller screen, select either Wired
or
Wireless mode.
2
The controller will then load Windows. The splash
screen will appear followed by the main menu screen.
3
To use the software database function, verify that
Enable Database
is checked on the
Preferences
menu.