RTR-4 Operator’s Manual
System Description, Setup, and Quick Start
120300 Rev. D
SAIC Proprietary
3-13
Standard Wired Configuration
In the wired configuration of the RTR-4 Imaging System, cabling
is used to interconnect the various components. The basic wired
configuration is shown here.
Setting Up the Wired Configuration
Description
Use this procedure to setup the standard RTR-4 Imaging System
in the wired configuration.
Prerequisites
Verify the following prerequisites are completed before beginning
this procedure:
• The RTR-4 components have been removed from their
transport cases.
• All needed batteries have sufficient charge or have been
recharged or replaced with new ones.
• A cleared, level workplace is available for setup and an
appropriate exclusion zone has been established.
Procedure RTR0001
Setup the wired configuration of the RTR-4 system as follows:
X-RAY
SOURCE
IMAGE
R
SUS
PECT
PAC
KAGE
CABLE
REEL
CONTROLLER
X-RAY SOURCE CABLE
COMMUNICATIONS CABLE
ADAPTER
CABLE
STEP
ACTION
1
Place the imager screen as close to the object to be
imaged as possible.
2
Place the X-ray source approximately 1m in front of
the imager, perpendicular to and level with the
imager screen.
3
Connect the yellow connector of the 3m (10ft) X-ray
Source cable to the imager and connect the other end
to the X-ray source.