Procedure RTR0002
Set up the wireless configuration of the RTR-4 system as follows:
STEP
ACTION
1
If not already mounted to the Imager, place the
Imager radio module in the imager mounting bracket
ensuring that the bulkhead connector is aligned and
secure the module with the quarter-turn clamps.
2
If the Imager radio module is to be used remotely
from the Imager, do the following:
• Connect the 3m (10ft) cable to the female
connector on the rear of the Imager.
• Place the Imager radio module in desired location.
• Connect other end of the 3m (10ft) cable to the
Imager radio module.
CAUTION
Antenna connectors are not keyed. Ensure antennas
are mated to the proper connector and correctly
aligned before tightening. Do not force antennas onto
connectors. Failure to comply may damage
equipment.
3
Attach
ANT 1
and
ANT 2
to their respective
connectors on the imager radio module.
4
Place the imager screen as close to the object to be
imaged as possible.
5
Place the X-ray source approximately 1m in front of
the imager, perpendicular to and level with the
imager screen.
NOTE
If it is desired to reduce the radio energy in the
vicinity of the object being X-Rayed, the X-Ray Source
Cable can be connected between the imager and the
source. This overrides the Imager radio module
control of the source by permitting the source to be
fired by signals sent through the cable.
6
Place the controller notebook in the selected area as
far from the imaging area as is appropriate to adhere
to exclusion zone requirements and other safety
regulations.