English
9
54
DISPLAY
Description
1.13.3.2.
It enables the function that allows to dispense beverages that have different prices if they are
dispensed with or without the cup.
Important
The Set1 = No cup option shall be used to set a discount for beverages dispensed without
the cup.
The machine does not allow to set discounts on the prices but the same result can be
achieved by using the second beverage set and setting the reduced price and deactivating
the cup dispensing for this set.
To save you from copying the recipes of the standard set to set 1, you can select a mode
that, in case of beverages without cup, automatically uses the recipes of the standard set
and the prices of set 1.
You only need to:
programme the beverage standard set with the desired products by setting for each one the
price with the cup included;
set the price of the corresponding beverages of set 1 to the desired value for the sale
without cup (set only the prices, the machine does not need the recipes and all other
beverage parameters of set 1 including the exclusion of the cup);
enter the "System Management" menu and within the cup settings set to YES the "Set1=no
cup" option;
set the mode for selecting beverages without cup.
Set the “Set 1 Pre-Selection” option to pre-selection and/or enable cup sensor (optional kit).
Set1=no cup
1.14.
Sugar dispensing settings.
Sugar
1.14.1.
Minimum delay between the time when the cup is dispensed and when the movable sugar
chute moves.
Cup Sugar Delay
1.14.2.
Sugar dispenser activation time setting for a single serving.
Sugar
1.14.3.
Set to “no” to have the sugar dispensed after the movable sugar chute downward
movement.
Sugar earlier
1.14.4.
Pause in the downward position of the sugar dispensing spout
Sugar Break
1.15.
settings for the management of the nozzle arm
nozzle arm
1.15.1.
By setting this option on YES the nozzle arm will move backwards into off position after the
dispensing of each beverage, this allows an instant release of the cup at the next beverage
dispensing and reduces the dispensing time.
Arm Backwards
1.16.
Display settings
Display settings
1.16.1.
Allows adjusting the display brightness (non-TFT models only).
Brightness
1.17.
Enables selection of whether the 24 V dc electromechanical pulse counter (optional - to be
connected to the CPU card) has to count the coffees or all dispensed beverages.
Pulse counter
Coffee
1.18.
Allows selecting which beverages will be enabled for multiple brewing and the number of
brewings.
Multiple beverage
…
1.18.1.
number of brewing procedures for multiple brewing
Multiple beverage
000
Summary of Contents for Cristallo 600 EVO