English
9
71
DISPLAY
Description
6.1.
It enables the control of slave 1 (or slave 2) through the Cristallo vending machine.
Enable
…
6.2.
NO = temperature control disabled, cooling group always OFF.
YES = temperature control enabled.
Enable Refrigerat.
…
6.3.
It selects the machine submodel: the values are 6S for the models with 6-spiral drawers (i.e.
Corallo) and 8S for those with 8-spiral drawers (i.e. Aliseo).
Optimises the fan settings for the specific case of the machine.
Model
…
6.4.
Enables / disables the “food mode”.
This mode enables the machine to check that the food area temperature is always lower than a set
value (alarm temperature). If the temperature exceeds this limit value for longer than the time set
for “Alarm max. time”, the machine deactivates the selections for the food shelves.
Food mode enabled
…
6.5.
[° C] Allows the setting of the temperature desired inside the machine [Range: 3 .. 30].
The control turns off the cooling group if the set value is reached and it turns it on if the
temperature is higher than the target plus 1°C (as long as the technical specifications of the
cooling group are respected).
Temperature 2
…
6.6.
[min] It allows setting how many minutes the cooling group will be switched off to carry out
the defrost [Range: 10 .. 100].
Defrost Time
…
6.7.
[hour] It allows setting the period of time between two defrost cycles [Range: 0.. 99].
Defrost Interval
…
6.8-9
Food mode settings
Food Mode Settings
…
6.8.10.
[min] Number of minutes allowed when the air temperature is higher than the alarm
temperature.
If the temperature exceeds the limit longer than the time set, the machine deactivates the
selections set as food [Range 0 .. 60].
Alarm timeout
…
6.8.11.
[min] When the opening of a door is detected or if the button 5 on the 5-buttons keypad is
pushed, the time set here will replace the usual timeout set by the previous option. [Range
0 .. 120].
This prevents the machine from entering error mode after product supply operations.
Please, remember that the machine must be supplied with products already at the correct
temperature for storage.
Refill allarm timeout
…
6.9.
Enables / disables the visualization of the temperature on the display during normal
operation.
Show temperature
…
6.10.
Photocells
6.10.1.
Enables / disables the photoelectric cell system.
Photocell Enabled
6.10.2.
[x100 ms] Period of extension of the spiral motor activation, when the fall of the product is
not detected. [Range 0 .. 5 ].
Max motor overtime
6.10.3.
Max. number of consecutive photoelectric cell errors in a selection, before this one is
deactivated.
If it is set to 0, the deactivation will never be carried out.
Disable selection