English
12
103
Cause
Error
Code
Machine without
snack slaves
Machine With
Snack Slaves
Notes / Recommended Intervention
Instant product boiler
temperature sensor
reading out of range
13
Models with 2 boilers
==>beverages with
instant products not
available
Beverages with
instant products
not available
Check the instant product boiler
(connections, thermostats, temperature
sensor).
Instant Models ==>
Vending machine out of
service
reading of coffee
boiler temperature
sensor out of range
14
Models with 2
boilers ==> coffee
beverages not
available
Models with 2
boilers ==> coffee
beverages not
available
Check the coffee boiler (connections,
thermostats, temperature sensor).
Models with 1
boiler ==>
Vending machine
out of service
Models with 1
boiler ==> no
beverage available
Cup holder movement
not detected
17
No more cups
warning
No more cups
warning
Warning report only in the LOG.
“No more cups” message is displayed.
The vending machine can still dispense beverages
without cups.
Fill in the cup columns.
Check the cup dispenser.
Brew group not
detected
20
Coffee beverages
not available
Coffee beverages
not available
Warning report only in the LOG.
"Coffee not available" message on the display.
Check the brew group inserting status.
Abnormal coffee
brewing flow
detected
22
Coffee beverages
not available
Coffee beverages
not available
Check the brew group cleaning.
Set a coarser coffee grind.
Check the flowmeter.
pump used beyond
maximum time limit
23
Warning only
Warning only
Check beverage programming; check flowmeter and
water circuit.
No filling of the
instant product boiler
24
Models with 2 boilers
==>beverages with
instant products not
available
Beverages with
instant products
not available
Check the instant product boiler water
circuit.
Instant Models ==>
Vending machine out of
service
Air sensor error
27
---
The slave is disabled
(only if the refrigerator
is enabled)
Check the air temperature sensor
connection.
Evaporator sensor
error
29
---
Warning only
Warning report only in the LOG.
Check the evaporator temperature sensor
connection.
Decimal point position
setting not consistent
with the payment
system
31
Vending machine
out of service
Vending machine
out of service
Check for consistency between decimal
point settings in the vending machine and
in the payment system
Credit management restart
32
Warning only
Warning only
Warning report only in the LOG.
Warning for normal
situation restoring
after abnormal flow
34
Warning only
Warning only
Warning report only in the LOG.
Check the ground coffee granulometry.
MDB slave error detected
35
Vending machine out of
service
Vending machine out of
service
Check the slave MDB mode (3 is the only mode
allowed).