English
9
69
DISPLAY
Description
5.13.
The following is necessary in order to operate with independent control:
1- enable independence control (menu "Capacity ctrl enabled");
2- programme the capacity of each spiral (menu "Capacity");
3- inform the vending machine each time it is refilled.
This information can be sent by pressing button 5 (black) on the 5-button keypad or by
selecting product "997" within 20 seconds of closing the door or switching the vending
machine on.
Once these first 20 seconds have passed, selecting "997" will have no effect.
When the vending machine is informed that refilling has taken place, it presumes that all
spirals have been filled up to the capacity specified during programming (step 2).
Once the maximum number of supplies has been reached, the spiral is disabled and the
product is listed as unavailable to the customer.
No error is reported.
Capacity
5.14.
Unit Management
Several motors can be grouped together within a unit. In this way, when the unit code is
selected, a product is dispensed from one of the unit motors.
Enabled groups
Summary of Contents for Cristallo 600 EVO