11.3.2
Capsule Coffee Brew Group
Maintenance
To
ensure
the
correct
operation
of
the
brew
group,
carry
out
the
operations
described
below each 8000 cycles.
This
unit
includes
very
sharp parts which may
cause
injuries
to
the
operator. Please be very
careful when performing
maintenance operations.
11.3.2.1
Removing the upper piercer
filter
Unscrew the 4 screws on the front of the brew group.
Unscrew the 4 screws located at the rear of the brew
group.
Widen the walls of the brew group slightly, and take out
the non-removable container for coffee capsules.
Unscrew the 3 screws holding the perforator in place.